PILOT LIGHT TROUBLESHOOTING CHART

PILOT LIGHT TROUBLESHOOTING CHART

Section A: Pilot light will not light (new installation).

Section C: Pilot light will not remain lit.

Is the manual gas shut-off valve, located in the supply line to the water heater, in the on position?

YES

Have you bled all the air

 

 

from the pilot tube and

 

NO

 

 

 

 

gas supply line?

 

 

 

YES

 

 

 

 

 

 

Turn the manual gas shut-off valve to

 

 

 

the on position and follow the lighting

NO

 

 

 

 

 

 

instructions on the front of the water heater.

While repeatedly depressing the igniter button, push in and hold the gas control/ temperature knob until the pilot is lit and maintains a stable flame, (status light will blink) then release the gas control/ temperature knob.

Check for insufficient combustion air.

Are the combustion air supply and ventilation openings

 

 

 

 

 

 

 

 

 

Correct size of

of sufficient size? See “Combustion Air Supply and

 

NO

 

 

 

 

 

openings to allow

 

 

Ventilation” section in this manual for requirements.

 

 

 

 

 

 

 

 

sufficient air.

 

YES

 

 

 

 

 

 

NOSection A: Pilot light will not light (new installation). Is there a furnace/air handler in the same room as the water heater?

YES

Is the igniter producing a

 

 

 

YES

spark?

 

 

 

 

NO

 

 

 

Follow the “Testing the Igniter

 

Set thermostat to desired temperature.

System” section in this manual.

 

 

 

 

Section B: Pilot light repeatedly goes out.

Does the return air duct for the furnace/ air handler draw its air from a separate location than the water heater? See the “Location Requirements” section and the “Combustion Air Supply” section.

YES

Is there proper drafting at the drafthood? See “Checking the NO Draft” section in this manual.

YES

 

 

 

Contact a local Heating,

 

 

 

Ventilation, Air-Conditioning

NO

 

 

 

 

& Refrigeration authorized

 

 

 

 

 

 

 

service provider to correct

 

 

 

the combustion air supply/

 

 

 

ventilation issue.

Check the vent system for restrictions/ obstructions and check the vent termination height. Refer to the “Installation Instructions” section of this manual for specific requirements.

Remove the burner door

 

 

 

 

 

Refer to the “Maintenance of

assembly. Are the flame-trap and

 

 

 

 

your Water Heater” section of this

 

NO

 

 

burner free from debris due to

 

 

 

 

manual for information on cleaning

 

 

 

 

 

 

 

 

excessive lint, dirt, dust or oil?

 

 

 

 

 

the flame-trap and burner.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does the flame-trap

 

 

 

 

Reassemble the heater and attempt to

 

show signs of

 

NO

 

 

 

 

 

 

return the heater to service. Does the

 

 

 

 

 

 

 

 

 

 

 

 

discoloration?

 

 

 

 

 

 

 

 

 

 

 

 

 

pilot remain lit?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shut-off the gas supply to the water heater at the manual gas shut-off valve, use the number on the cover of this manual to contact Customer Service.

Reference the number on the cover of this manual for service information.

NOTE: If you are still experiencing difficulties after following the steps in sections A, B, and C, use the number on the cover of this manual to contact Customer

Service.

NO

Go to section C.

Set to desired temperature.

Does the diagnostic status light on the gas control valve/thermostat give

a two flash error code?

YES

Refer to the “Replacing the Pilot Assembly” instructions in the manual.

Reassemble and restore to service.

31

Page 31
Image 31
American Water Heater 318935-003 Pilot Light Troubleshooting Chart, Section A Pilot light will not light new installation