American Water Heater (A)BCG38T500-8P manual TEST 2 POLARITY CHECK, Conditions, Test, then, Ground

Models: (A)BCG38T500-8P (A)BCG385T500-8N

1 40
Download 40 pages 7.85 Kb
Page 28
Image 28
TEST 2: POLARITY CHECK

TROUBLESHOOTING

TEST 2: POLARITY CHECK

Conditions:

No hot water

Green “Power” LED is on.

Tank is more than 5° F below temperature dial setting.

Red ignition control board diagnostic LED is flashing 6 times between pauses.

Red, diagnostic “Call for Heat” LED-OFF.

Figure 20

BL

BR

BK

W

RR

W

TO EARTH

GROUND

R

 

 

 

 

 

 

1a 1 1b

 

 

 

 

 

 

 

 

 

R

 

 

HOT 120 VAC

BL NEUTRAL

1a 1 1b EARTH GROUND

IGNITOR/FLAME

SENSOR

120 VAC CIRCUIT FACTORY INSTALLED BY INSTALLER
120 V.

Ground

 

 

Figure 21

 

 

 

 

TEST 2

Polarity Check

 

Check from on/off switch center and white wire terminals to ground

 

 

 

IF

then

 

115-125 VAC is not present

see Test 1.

 

Voltage is present white (right terminal) to ground

reverse supply wire connections. Polarity is reversed.

 

but not black (center terminal) to ground

 

 

 

 

Servicing should only be performed by a Qualified Service Agent

28

Page 28
Image 28
American Water Heater (A)BCG38T500-8P manual TEST 2 POLARITY CHECK, Conditions, Test, then, Troubleshooting, Polarity Check