TROUBLESHOOTING
TEST 4: UPPER TEMPERATURE PROBE CONTINUITY CHECK
Conditions:
•Power On - Water below temperature set point.
•Red, water heater control “Reset Status”
•“Call For Heat” LED off.
TEST 4 | Upper Temperature probe continuity check | |||
Red wire to red wire - Turn supply power “Off” for this test | ||||
|
| |||
IF | then | |||
Test indicates no continuity | replace probe. | |||
Continuity is indicated | Probe should be okay. | |||
|
| (Also verify Ohms resistance for water temperature. Reading will be approximate.) | ||
|
|
|
| |
|
|
|
|
Figure 23
Table 4
| OHMS RESISTANCE TABLE | |
|
|
|
° F |
| Ohms |
70° |
| 11,884 |
120° |
| 3,759 |
140° |
| 2,488 |
180° |
| 1,169 |
Servicing should only be performed by a Qualified Service Agent