TROUBLESHOOTING
TEST 3: CONTINUITY CHECK OF HIGH LIMIT (ECO)
Conditions:
•Power On – No Hot Water
•Red, heater control “Call for Heat” LED – on
•Red ignition control board diagnostic LED – 4 Flashes
•Note LED Flash Code before resetting water heater control.
•See Ignition Control Board: Error Codes.
•Turn Power OFF.
Figure 22
| Continuity check of ECO | |
TEST 3 | (energy | |
Black to Black wires of upper probe. | ||
| ||
| Power is off. | |
IF | Then | |
continuity is indicated | opens at 203° F; closes at 193° F. If water is below 193° F, continuity is correct. | |
(ZERO “0.0” Resistance) |
| |
continuity is not present | replace ECO sensor if water temperature is below 193° F. | |
(meter reads “0.L”) |
| |
water is less than 120° F | • reset status LED should be on. | |
| • replace heater control if control will not manually reset. |
Servicing should only be performed by a Qualified Service Agent
29