TROUBLESHOOTING
TEST 11: WATER HEATER SHUTTING OFF BELOW SETTING
Conditions:
•Main burner ignited
•Stored water is below temperature setting more than 5° F (Tank Average).
•Power off
•Plug disconnected from heater control board receptacle E3 and E4
E3
E4
|
| Figure 30 |
|
| |
TEST 11 | WATER HEATER SHUTTING OFF BELOW SETTING | |
(Water Temperature Circuit Check - Continuity) | ||
IF | then | |
Continuity check pin to pin of lower temperature | See Test 4. | |
probe shows 1 or 0 (E4) | • | check wiring and plug connections to heater control board receptacle E4. |
| • | replace lower temperature probe. |
Continuity check red wire pin to red wire pin on | See Test 4. | |
upper temperature sensor shows 1 or 0 (E3) | • | check wiring and plug connections to heater control board receptacle. |
| • | replace upper temperature probe. |
All above checks are okay | • | Check wiring and plug connections to heater control board receptacle. |
| • | Replace upper temperature probe. |
|
|
|
Servicing should only be performed by a Qualified Service Agent