TEST 7: BLOWER ON, BLOWER PROVER SWITCH CLOSED, NO IGNITER OPERATION

TROUBLESHOOTING

TEST 7: BLOWER ON, BLOWER PROVER SWITCH CLOSED, NO IGNITER OPERATION

Conditions:

Power on, but no power to igniter

Plugs in receptacles

Blower (Draft Inducer) on

24V at ignition board E1, Pin 10

Check E1 pin 10 - 24V

Check E4 pin 4 to Ground

Ground

Check E4 pin 2 to Ground

Ground

Continuity

Test

4321

E4 Plug

 

 

 

Figure 26

 

 

 

 

 

 

TEST 7

Voltage check and continuity check of hot surface igniter circuit

 

 

Continuity check - Power off- Plug removed from E4 receptacles.

 

 

 

Nominal 80 VAC check - Plug in E4- Power on.

 

 

IF

then

 

 

Continuity is not indicated between E4 plug

check wiring and connection from E4 plug to HSI receiving plug.

 

 

pin 2 to 4.

replace HSI Assembly.

 

 

Continuity is present

Resistance should be between 11 and 20 Ohms at a temperature of 77°F.

 

 

Voltage is not present between E4, Pin 2 to ground

Replace ignition board.

 

 

Voltage is present

Continue

 

 

Voltage is not present between E4, Pin 4 to

check wiring and plug connections to hot surface igniter (HSI).

 

 

ground

replace HSI if needed.

 

 

Voltage is present

Note ignition board flash code LED. Hot surface igniter (HSI) should work.

 

 

 

 

 

 

 

 

 

 

 