AMX Anterus manual Reader Configuration Options

Models: Anterus

1 38
Download 38 pages 46.17 Kb
Page 29
Image 29

Anterus Configuration Manager

Reader Configuration Options

The top section of this page provides configuration options for the selected ANT-RDR:

FIG. 26 Reader Configuration Options

Reader Configuration Page

• Reader ID:

Indicates the Device ID for the selected ANT-RDR, as specified via the

Reader Address:Indicates the AxLink Device Address for the selected ANT-RDR. In the Global Registery page, the Reader ID is always "Global", and cannot be changed.

Acquired Threshold (1...255): The ANT-RDR will notify the Master that a Tag's signal has been acquired when its RSSI signal is above the Acquired Threshold value.

The allowed range is 1 (min.) to 255 (max)

Default = 200

Lost Threshold (0...254): The ANT-RDR will notify the Master that a Tag's signal has been lost when its RSSI signal is below the Lost Threshold value.

The allowed range is 0 (min.) to 254 (max)

Default = 50

• Sensitivity (1...255)

The Sensitivity setting is used to reduce the message traffic between the

 

ANT-RDR and the Master:

 

The ANT-RDR remembers the last RSSI value sent to the Master for each

 

Tag it has acquired. On the next poll, only Tags whose current RSSI value is

 

outside the range of the last sent RSSI value +/- the Sensitivity value

 

entered here will be sent to the Master.

The allowed range is 1 (min.) to 255 (max)

Default = 30

Tag-Lost Timeout (30...255 Use this option to specify the period time allowed to continue monitoring

seconds)

Tags whose RFID signal has dropped below the level specified in the Lost

 

Threshold.

 

• If a Tag’s RSSI signal has dropped below the Lost Threshold level, and is

 

re-acquired by the Reader within the time period specified here, it will

 

automatically resume normal functionality.

 

• Conversely, if a Tag’s RSSI signal drops below the Lost Threshold level,

 

and is not re-acquired within the specified time period, the Reader will no

 

longer monitor for that Tag. Therefore, once the timeout period has

 

elapsed, the Tag will not be automatically re-acquired, and must be

 

manually re-entered into the system.

 

• Default = 30 seconds.

 

 

• Status (Online/Offline)

Indicates the current status of the selected ANT-RDR (display-only).

Anterus RFID Solution

25

 

 

Page 29
Image 29
AMX Anterus manual Reader Configuration Options