Communication and Firmware Update
11.Select Tools > Reboot the Master Controller to access the Reboot the Master dialog, then click Continue to reboot the Master and incorporate any changes. Allow 20 - 30 seconds for the Master to reboot. The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait until the STATUS LED is the only LED to blink.
12.Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default System value is one (1).
13.
If the connection fails to establish, a Connection Failed dialog appears. Try selecting a different IP Address if communication fails.
Press the Retry button to reconnect using the same communication parameters. Press the Change button to alter your communication parameters and repeat steps 2 thru 10.
14.Once the particular System Master is configured for communication via an IP Address, remove the RS232 connector from the Program port on the NetLinx Master.
Installing New NetLinx Master Firmware via an IP
1.Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default System value is one (1).
2.
3.After the Communication Verification dialog window verifies active communication between the PC and the Master, verify the NetLinx Master appears in the OnLine Tree tab of the Workspace window (FIG. 23).
Showing the current version of the NetLinx Studio
FIG. 23 Initial NetLinx Workspace window (showing the OnLine Tree tab)
The current firmware version of the Master is displayed to the right of the device.
29 |
| |
|
|
|