Installation and Wiring
Wiring length guidelines
The Master requires a 12 VDC power from a PSN to operate properly. The unit should only have one source of incoming power.
Using more than one source of power to the Master can result in damage to the internal components and a possible burn out.
An auxiliary 12 VDC power supply can provide power to the Master. Refer to the following table for wiring length information:
Wiring Length Guidelines @ 750 mA
Wire Size | Maximum wiring length |
|
|
18 AWG | 156.49 feet (46.69 meters) |
|
|
20 AWG | 99.01 feet (30.18 meters) |
|
|
22 AWG | 61.73 feet (18.81 meters) |
|
|
24 AWG | 38.91 feet (11.86 meters) |
|
|
Wiring a 2-pin power connection
To use the NetLinx
PWR +
GND -
To the ME260
FIG. 5
NetLinx Power Supply
Using the 4-pin mini-Phoenix connector for data and power
Connect the
To the ME260 | To the external NetLinx device | |
AXlinx/PWR connector | ||
|
Top view |
|
|
|
|
|
|
|
GND - | AXP/TX | AXM/RX | PWR + | GND - | AXP/TX | AXM/RX | PWR + |
FIG. 6
Top view
| 8 | |
|
|
|