Program Port Commands (Cont.)

Programming

Program Port Commands (Cont.)

Command

Description

 

 

SET DATE

Prompts you to enter the new date for the Master Card.

 

When the date is set on the Master Card, the new date will be reflected on

 

all devices in the system that have clocks (i.e. touch panels). By the same

 

token, if you set the date on any system device, the new date will be

 

reflected on the system’s Master, and on all connected devices.

 

This will not update clocks on devices connected to another Master (in

 

Master-to-Master systems).

 

Example:

 

 

>SET DATE

 

 

Enter Date: (mm/dd//yyyy) ->

 

 

TIME

Displays the current time on the Master Card.

 

Example:

 

 

>TIME

 

 

13:42:04

 

 

 

SET TIME

Prompts you to enter the new time for the Master Card.

 

When the time is set on the Master Card, the new time will be reflected on

 

all devices in the system that have clocks (i.e. touch panels). By the same

 

token, if you set the time on any system device, the new time will be

 

reflected on the system’s Master, and on all connected devices.

 

This will not update clocks on devices connected to another Master (in

 

Master-to-Master systems).

 

Example:

 

 

>SET TIME

 

 

Enter Date: (hh:mm:ss) ->

 

 

DEVICE STATUS <D:P:S>

Displays a list of all active (on) channels for the specified D:P:S. Enter

 

DEVICE STATUS without the D:P:S variable, the Master Card displays

 

ports, channels, and version information.

 

Displays status of the specified Master.

 

Example (on a local Master):

 

>DEVICE STATUS [0:1:0]

 

Device 0 AMX Corp.,Master,v2.10.75 contains 1 Ports.

 

Port

1 - Channels:256 Levels:8

 

 

MaxStringLen=64 Types=8 bit MaxCommandLen=64 Types=8 bit

 

 

The following input channels are on:None

 

 

The following output channels are on:None

 

 

The following feedback channels are on:None

 

 

Level 1=0 Supported data types=UByte,UInt

 

 

Level 2=0 Supported data types=UByte,UInt

 

 

Level 3=0 Supported data types=UByte,UInt

 

 

Level 4=0 Supported data types=UByte,UInt

 

 

Level 5=0 Supported data types=UByte,UInt

 

 

Level 6=0 Supported data types=UByte,UInt

 

 

Level 7=0 Supported data types=UByte,UInt

 

 

Level 8=0 Supported data types=UByte,UInt

 

 

 

DNS LIST <D:P:S>

Displays:

 

 

• Domain suffix·

 

• Configured DNS IP Information

 

Example:

 

 

>DNS LIST [0:1:0]

 

Domain suffix:amx.com

 

The following DNS IPs are configured

 

Entry 1-192.168.20.5

 

Entry 2-12.18.110.8

 

Entry 3-12.18.110.7

 

 

 

 