AMX instruction manual NXC-ME260 Specifications, Product Information

Models: NXC-ME260

1 106
Download 106 pages 58.54 Kb
Page 8
Image 8
Specifications

Product Information

Specifications

NXC-ME260 Specifications

Dimensions (HWD):

 

NXC Card

1.38" x 5.43" x 9.25" (35.1 mm x 138.0 mm x 235.0 mm)

 

 

NXS Module

1.64" x 5.55" x 9.28" (41.7 mm x 141.0 mm x 236.0 mm)

 

 

Weight:

NXC-ME260 only: 0.55 lbs (0.25 kg)

 

NXC-ME260 with NXS-NMS module: 1.95 lbs (0.88 kg)

 

 

Power Consumption:

750 mA @ 12 VDC

 

 

Memory:

Compact Flash: 32 MB standard (upgradeable)

 

Volatile: 16 MB

 

Non-volatile: 1 MB

 

 

Microprocessor:

Coldfire® 5407 (32-bit)

Enclosure:

Metal with black matte finish.

 

 

Front Faceplate:

Plastic grey with translucent viewing window.

 

 

Front Panel Components:

 

Program port

DB9 (male) connector supports RS-232 communications to your PC for system

 

programming and diagnostics. You set the port's communication speed with

 

the Baud Rate DIP switch. See the Setting the Program Port DIP

 

Switch section on page 5 for details.

 

Note: There are Program ports located on the front and rear panels of the

 

Master card for easy access. Because these ports share the same circuitry,

 

you should never use both at the same time; doing so will result in

 

communication and/or programming errors.

 

 

Status LED

Green LED lights to indicate that the system is programmed and

 

communicating properly.

 

 

Output LED

Red LED lights when the Master transmits data, sets channels On and Off,

 

sends data strings, etc.

 

 

Input LED

Yellow LED lights when the Master receives data from button pushes, strings,

 

commands, channel levels, etc.

 

 

Front Panel LEDs -

These LEDs also display special blink patterns when a mode is activated. See

blink patterns

the Modes and Front Panel LED Blink Patterns section on page 7 for details.

 

 

Program Port DIP Switch

8-position DIP switch located behind the front panel for setting the baud rate for

 

the Program port.

 

• Available baud rate settings are 9600, 38,400 (default), 57,600 and 115,200

 

(bps). Refer to the Setting the Program Port DIP Switch section on page 5 for

 

details.

 

 

Rear Panel Components:

 

PWR connector

2-pin (male) green captive-wire connector for 12 VDC power supply.

 

 

EXPANSION OUT port

RJ11 connector connects to an AXB-SPE Server Port Expander.

 

 

Ethernet 10/100 port

RJ-45 Ethernet 10/100 connector. The Ethernet port automatically negotiates

 

the connection speed (10 Mbps or 100 Mbps) and whether to use half duplex

 

or full duplex mode.

 

 

Ethernet 10/100 LEDs

LEDs that show communication activity, connections, speeds, and mode

 

information:

 

A-activity - Yellow LED blinks when receiving Ethernet data packets.

 

L-link - Green LED lights when the Ethernet cables are connected and

 

terminated correctly.

 

• SPEED - Green LED lights when transmitting data at 100 Mbps, and is Off

 

when transmitting at 10 Mbps.

 

FD-full duplex - Green LED lights when running in full duplex mode, and is Off

 

when running half duplex mode.

 

 

 

2

NXC-ME260 NetLinx Master-Ethernet Card/Module

 

 

 

Page 8
Image 8
AMX instruction manual NXC-ME260 Specifications, Product Information