AMX NXC-ME260 Programming, Program Port Commands, PC COM Port Communication Settings

Models: NXC-ME260

1 106
Download 106 pages 58.54 Kb
Page 95
Image 95
Programming

Programming

Programming

The NetLinx programming language allows numbers in the range 0-32,767. Device 0 refers to the Master Card; numbers greater than 32,767 are reserved for internal use only.

The NetLinx programming language requires a Device:Port:System (D:P:S) syntax where Axcess expects only a device number. The NetLinx D:P:S triplet variable is expressed as:

DEVICE:PORT:SYSTEM

where:

Device: 16-bit integer representing the device number (0-32,767). 0 = the local Master.

• Port:

16-bit integer representing the port number (in the range 1 through the number of

 

ports on the NetLinx Master or device).

• System:

16-bit integer representing the system number (0 = this system).

Program Port Commands

The Program port commands listed in the Program Port Commands table below can be sent directly to the Master Card using a terminal program (i.e. Telnet). In order for Telnet to be effective, you must initiate a session with the master. Be sure that your PC's COM port and terminal program's communication settings match those in the following table.

PC COM Port Communication Settings

Baud

38400 (default)

 

 

Parity

none

 

 

Data Bits

8

 

 

Stop Bits

1

 

 

Flow Control

none

 

 

In your terminal program, type "Help" or a "?" <Enter> to display the Program port commands

listed below.

Program Port Commands

Command

Description

 

 

ECHO OFF

Disables terminal character's echo (display) function.

 

 

ECHO ON

Enables terminal character's echo (display) function.

 

 

DATE

Displays the current date and day of the week.

 

Example:

 

>DATE

 

10/31/2001 Wed

 

 

NXC-ME260 NetLinx Master-Ethernet Card/Module

89

 

 

 

 

Page 95
Image 95