Programming
Programming
The NetLinx programming language allows numbers in the range
The NetLinx programming language requires a Device:Port:System (D:P:S) syntax where Axcess expects only a device number. The NetLinx D:P:S triplet variable is expressed as:
DEVICE:PORT:SYSTEM
where:
•Device:
• Port: | |
| ports on the NetLinx Master or device). |
• System: |
Program Port Commands
The Program port commands listed in the Program Port Commands table below can be sent directly to the Master Card using a terminal program (i.e. Telnet). In order for Telnet to be effective, you must initiate a session with the master. Be sure that your PC's COM port and terminal program's communication settings match those in the following table.
PC COM Port Communication Settings
Baud | 38400 (default) |
|
|
Parity | none |
|
|
Data Bits | 8 |
|
|
Stop Bits | 1 |
|
|
Flow Control | none |
|
|
In your terminal program, type "Help" or a "?" <Enter> to display the Program port commands
listed below.
Program Port Commands
Command | Description |
|
|
ECHO OFF | Disables terminal character's echo (display) function. |
|
|
ECHO ON | Enables terminal character's echo (display) function. |
|
|
DATE | Displays the current date and day of the week. |
| Example: |
| >DATE |
| 10/31/2001 Wed |
|
|