AMX NXC-ME260 instruction manual Resetting the Factory Default System and Device Values

Models: NXC-ME260

1 106
Download 106 pages 58.54 Kb
Page 31
Image 31
Resetting the Factory Default System and Device Values

Communication and Firmware Update

Resetting the Factory Default System and Device Values

1.Access the Device Addressing dialog (FIG. 19 on page 23) by either one of these two methods:

Right-click on any system device listed in the Workspace and select Device Addressing.

Select Diagnostics > Device Addressing from the Main menu.

2.Click the Set Device/System to Factory Default button. This resets both the system value and device addresses (for definable devices) to their factory default settings. The system information (in the OnLine Tree tab of the Workspace window) refreshes and then displays the new information.

By setting the system to its default value (#1), Modero panels that were set to connect to the Master on another System value will not appear in the OnLine Tree tab of the Workspace window.

For example: A Modero touch panel was previously set to System #2. The system is then reset to its default setting of System #1 and then refreshed from within the Workspace window. The panel will not reappear until the system is changed (from within the System Connection page on the Modero) to match the new value and both the Master and panel are rebooted.

3.Click Done to close the Device Addressing dialog.

4.Select Tools > Reboot the Master Controller to access the Reboot the Master dialog, then click Continue to reboot the Master and incorporate any changes. Allow 20 - 30 seconds for the Master to reboot.

5.Right-click the associated System number (from the OnLine Tree tab of the Workspace window) and select Refresh Whole Network to refresh of all project systems, establish a new connection to all Masters, and refresh the System list with devices on that system.

6.Use Ctrl+S to save your existing NetLinx Project with the new changes.

Obtaining the Master’s IP Address (using DHCP)

Verify there is an active Ethernet connection attached to the rear of the Master before beginning these procedures.

1.Select Diagnostics > Network Addresses from the Main menu to access the Network Addresses dialog.

2.Verify the System number corresponds to the value previously assigned in the Device Addressing tab and verify that zero (0) is entered into the Device field.

The system value must correspond to the Device Address entered in the Device Addressing dialog. Refer to the Setting the System Value section on page 21 for more detailed instructions on setting a system value.

3.Verify that NetLinx appears in the Host Name field.

4.Click the Use DHCP radio button from the IP Address section (FIG. 20).

5.Click the Get IP Information button to read the IP Address obtained by the Master from the DHCP Server and configure the unit for DHCP usage.

NXC-ME260 NetLinx Master-Ethernet Card/Module

25

 

 

 

 

Page 31
Image 31
AMX NXC-ME260 Resetting the Factory Default System and Device Values, Obtaining the Master’s IP Address using DHCP