Programming

Page Commands (Cont.)

@DPG

Syntax:

Delete a specific

"'@DPG-<popup page name>;<popup group name>'"

popup page from

Variable:

specified popup

popup page name = 1 - 50 ASCII characters. Name of the popup page.

group if it exists.

popup group name = 1 - 50 ASCII characters. Name of the popup group.

 

 

Example:

 

SEND_COMMAND Panel,"'@DPG-Popup1;Group1'"

 

Deletes the popup page ’Popup1’ from the popup group ’Group1’.

 

 

@PDR

If the flag is set, the popup will return to its default location on show instead of its last drag

Set the popup

location.

 

location reset flag.

Syntax:

 

"'@PDR-<popup page name>;<reset flag>'"

 

Variable:

 

popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed

 

On.

 

reset flag = 1 = Enable reset flag

 

0 = Disable reset flag

 

Example:

 

SEND_COMMAND Panel,"'@PDR-Popup1;1'"

 

Popup1 will return to its default location when turned On.

 

 

@PHE

Syntax:

Set the hide effect

"'@PHE-<popup page name>;<hide effect name>'"

for the specified

Variable:

popup page to the

named hide effect.

popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed

On.

 

 

hide effect name = Refers to the popup effect names being used.

 

Example:

 

SEND_COMMAND Panel,"'@PHE-Popup1;Slide to Left'"

 

Sets the Popup1 hide effect name to ’Slide to Left’.

 

 

@PHP

Only 1 coordinate is ever needed for an effect; however, the command will specify both.

Set the hide effect

This command sets the location at which the effect will end at.

position.

Syntax:

 

"'@PHP-<popup page name>;<x coordinate>,<y coordinate>'"

 

Variable:

 

popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed

 

On.

 

Example:

 

SEND_COMMAND Panel,"'@PHP-Popup1;75,0'"

 

Sets the Popup1 hide effect x-coordinate value to 75 and the y-coordinate value to 0.

 

 

@PHT

Syntax:

Set the hide effect

"'@PHT-<popup page name>;<hide effect time>'"

time for the

Variable:

specified popup

popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed

page.

On.

 

 

hide effect time = Given in 1/10ths of a second.

 

Example:

 

SEND_COMMAND Panel,"'@PHT-Popup1;50'"

 

Sets the Popup1 hide effect time to 5 seconds.

 

 

136

NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom

Page 150
Image 150
AMX NXD-700Vi manual @Dpg, @Pdr, @Phe, @Php, @Pht

NXD-700Vi specifications

The AMX NXD-700Vi is a cutting-edge touchscreen control panel designed to enhance the user experience in various AV environments, including conference rooms, classrooms, and home theaters. Featuring a sleek and modern design, the NXD-700Vi combines advanced technology with an intuitive interface, making it an ideal solution for both commercial and residential applications.

At the heart of the NXD-700Vi is a 7-inch high-resolution LCD touchscreen, which delivers vibrant colors and crisp details, ensuring that users can easily navigate through the various functionalities and options available. The screen is equipped with an anti-glare coating that allows for optimal visibility in different lighting conditions, making it suitable for any setting.

One of the standout features of the NXD-700Vi is its customizable interface. Users can personalize the layout and graphics, tailoring the control panel to meet specific needs or branding requirements. This flexibility not only enhances usability but also provides a unique touch that can resonate with the intended audience.

The NXD-700Vi employs advanced networking capabilities, allowing for seamless integration with a wide array of AV devices and systems. It supports Ethernet connectivity, enabling users to control various devices from anywhere within the network. This flexibility is particularly useful in large installations where managing multiple systems can be cumbersome.

In addition to its networking capabilities, the NXD-700Vi incorporates infrared (IR) control, enabling it to communicate directly with many AV components. This dual-functionality ensures that users can manage their complete AV setup, including projectors, audio systems, and lighting, all from a single interface.

Another notable characteristic of the NXD-700Vi is its robust security features. The panel can be configured to restrict access to certain functions or settings, ensuring that sensitive content or equipment is protected from unauthorized use. This is particularly critical in environments where information security is paramount.

The unit is also designed for easy installation and management. With a built-in web server, users can configure the NXD-700Vi remotely, streamlining setup and maintenance. This feature reduces the need for on-site visits, saving both time and resources.

Overall, the AMX NXD-700Vi stands out as a sophisticated, versatile solution for modern AV control needs. With its intuitive touchscreen, customizable interface, and comprehensive integration capabilities, it is an essential tool for enhancing control and interaction in both commercial and residential environments.