Configuring Communication

Master Connection to a Virtual Master via Ethernet

When configuring your panel to communicate with a Virtual Master (on your PC) via wireless Ethernet, the Master IP/URL field must be configured to match the IP Address of the PC and make sure to use the Virtual System value assigned to the Virtual Master within NetLinx Studio.

Before beginning:

1.Verify the panel has been configured to communicate with the Wireless Access Point and verify the signal strength quality bargraph is On.

2.Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx Studio 2 > NetLinx Studio 2).

3.Select Settings > Master Communication Settings, from the Main menu to open the Master Communication Settings dialog (FIG. 40).

Enter this IP into the Master IP/URL field on the

System Settings page

IP Addresses of computer (also obtained by using the Start > Run > cmd command)

FIG. 40 Assigning Communication Settings and TCP/IP Settings for a Virtual Master

4.Click the Communications Settings button to open the Communications Settings dialog.

5.Click on the NetLinx Master radio button (from the Platform Selection section) to indicate that you are working as a NetLinx Master.

6.Click on the Virtual Master radio box (from the Transport Connection Option section) to indicate you are wanting to configure the PC to communicate with a panel. Everything else such as the Authentication is greyed-out because you are not going through the Master’s UI.

7.Click the Edit Settings button (on the Communications Settings dialog) to open the Virtual NetLinx Master Settings dialog (FIG. 40).

8.From within this dialog enter the System number (default is 1) and note the IP Address of the target PC being used as the Virtual Master. This IP Address can also be obtained by following these procedures:

On your PC, click Start > Run to open the Run dialog.

Enter cmd into the Open field and click OK to open the command DOS prompt.

From the C:\> command line, enter ipconfig to display the IP Address of the PC. This information is entered into the Master IP/URL field on the panel.

9.Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx Studio application.

10.Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The default System value is one.

11.Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list.

12.Connect the terminal end of the PS4.4 power cable to the 12 VDC power connector on the side of the stand-alone touch panel.

56

NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom

Page 70
Image 70
AMX NXD-700Vi manual Master Connection to a Virtual Master via Ethernet

NXD-700Vi specifications

The AMX NXD-700Vi is a cutting-edge touchscreen control panel designed to enhance the user experience in various AV environments, including conference rooms, classrooms, and home theaters. Featuring a sleek and modern design, the NXD-700Vi combines advanced technology with an intuitive interface, making it an ideal solution for both commercial and residential applications.

At the heart of the NXD-700Vi is a 7-inch high-resolution LCD touchscreen, which delivers vibrant colors and crisp details, ensuring that users can easily navigate through the various functionalities and options available. The screen is equipped with an anti-glare coating that allows for optimal visibility in different lighting conditions, making it suitable for any setting.

One of the standout features of the NXD-700Vi is its customizable interface. Users can personalize the layout and graphics, tailoring the control panel to meet specific needs or branding requirements. This flexibility not only enhances usability but also provides a unique touch that can resonate with the intended audience.

The NXD-700Vi employs advanced networking capabilities, allowing for seamless integration with a wide array of AV devices and systems. It supports Ethernet connectivity, enabling users to control various devices from anywhere within the network. This flexibility is particularly useful in large installations where managing multiple systems can be cumbersome.

In addition to its networking capabilities, the NXD-700Vi incorporates infrared (IR) control, enabling it to communicate directly with many AV components. This dual-functionality ensures that users can manage their complete AV setup, including projectors, audio systems, and lighting, all from a single interface.

Another notable characteristic of the NXD-700Vi is its robust security features. The panel can be configured to restrict access to certain functions or settings, ensuring that sensitive content or equipment is protected from unauthorized use. This is particularly critical in environments where information security is paramount.

The unit is also designed for easy installation and management. With a built-in web server, users can configure the NXD-700Vi remotely, streamlining setup and maintenance. This feature reduces the need for on-site visits, saving both time and resources.

Overall, the AMX NXD-700Vi stands out as a sophisticated, versatile solution for modern AV control needs. With its intuitive touchscreen, customizable interface, and comprehensive integration capabilities, it is an essential tool for enhancing control and interaction in both commercial and residential environments.