OPERATION

SE-4200/4400 WATER FILTRATION SYSTEM

OPERATION

Filtration Process

The filtration process includes a Filtration Cycle and a Backwash Cycle.

During the Filtration Cycle, water enters the system inlet port and passes through the filter elements before exiting via the Permeate outlet.

This system is designed so that no valves are powered during the Filtration Cycle. This allows water to contin- ue to be filtered during a power outage and it minimizes electrical power consumption.

After a period of time, the filters have to be cleaned. This is accomplished through the Backwash Cycle.

During the Backwash Cycle, filtered water from one of the cartridges is fed back through the other cartridge to break up any debris collected on the membrane walls.

The Backwash Cycle includes a forward flush step which then uses the feed water to flush away the loos- ened debris from the cartridge’s membranes. The valves are only powered during the flushing cycle and in STOP MODE.

NOTE: Both the Filtration and Backwash cycles can be completely automated through the Control Panel. See the Programming section within this manual.

Operating Controls (Figure 2)

Control

Function

Button

 

FLUSH

Performs a QUICK FLUSH operation

 

when actuated during FILTER MODE or

 

STOP MODE.

RUN

Initializes and starts an internal timer for

 

the automatic flushing of the system and

 

puts the system into FILTER MODE.

 

When pressed, the system performs a

 

BORE AIR RELEASE operation before

 

entering FILTER MODE.

STOP

Stops all functions immediately; pow-

 

ers all valves. Closes the Input and

 

Permeate ports/valves and opens all

 

Drain ports/valves.

F1

Starts the Backwash Cycle during

 

FILTER MODE or STOP MODE.

F2

Service Feature. Valve, Transducer,

 

and alarm status can be viewed and

 

changed. Press and hold this button for

 

a minimum of 3 seconds to access this

 

mode.

CURSOR

Up/Down/Left/Right arrow buttons

 

are used to scroll through the choices

 

shown in the Message Display window.

MENU

Allows access to program and setting

 

features .

ENTER

Used to confirm settings in MENU

 

mode.

FLUSH

Filtration ProcessOperating Controls (Figure 2) Message Display ControlFunction

RUN

STOP

MENU

F1

F2

ENTER

Figure 2. Operating Controls