OPERATION
Filtration Process
The filtration process includes a Filtration Cycle and a Backwash Cycle.
During the Filtration Cycle, water enters the system inlet port and passes through the filter elements before exiting via the Permeate outlet.
This system is designed so that no valves are powered during the Filtration Cycle. This allows water to contin- ue to be filtered during a power outage and it minimizes electrical power consumption.
After a period of time, the filters have to be cleaned. This is accomplished through the Backwash Cycle.
During the Backwash Cycle, filtered water from one of the cartridges is fed back through the other cartridge to break up any debris collected on the membrane walls.
The Backwash Cycle includes a forward flush step which then uses the feed water to flush away the loos- ened debris from the cartridge’s membranes. The valves are only powered during the flushing cycle and in STOP MODE.
NOTE: Both the Filtration and Backwash cycles can be completely automated through the Control Panel. See the Programming section within this manual.
Operating Controls (Figure 2)
Control | Function |
Button |
|
FLUSH | Performs a QUICK FLUSH operation |
| when actuated during FILTER MODE or |
| STOP MODE. |
RUN | Initializes and starts an internal timer for |
| the automatic flushing of the system and |
| puts the system into FILTER MODE. |
| When pressed, the system performs a |
| BORE AIR RELEASE operation before |
| entering FILTER MODE. |
STOP | Stops all functions immediately; pow- |
| ers all valves. Closes the Input and |
| Permeate ports/valves and opens all |
| Drain ports/valves. |
F1 | Starts the Backwash Cycle during |
| FILTER MODE or STOP MODE. |
F2 | Service Feature. Valve, Transducer, |
| and alarm status can be viewed and |
| changed. Press and hold this button for |
| a minimum of 3 seconds to access this |
| mode. |
CURSOR | Up/Down/Left/Right arrow buttons |
| are used to scroll through the choices |
| shown in the Message Display window. |
MENU | Allows access to program and setting |
| features . |
ENTER | Used to confirm settings in MENU |
| mode. |
FLUSH
Message Display
RUN | STOP | MENU |
F1 | F2 | ENTER |
Figure 2. Operating Controls
10 | P/N 1010852 Rev. C 04/06 |