Antunes, AJ SE-4200/4400 WATER FILTRATION SYSTEM, OPERATION continued, Reset Defaults Mode

Models: SE-4200/4400

1 24
Download 24 pages 32.42 Kb
Page 13
Image 13
RESET DEFAULTS MODE

SE-4200/4400 WATER FILTRATION SYSTEM

OPERATION (continued)

7.

The system displays the FLUSH BY PRESS DIFF

 

RESET DEFAULTS MODE

 

display. If the filtration system came with pressure

1.

From the FILTER MODE display, press the Stop

 

transducers installed, this feature is available.

 

 

 

button. The system displays the STOP MODE dis-

 

If no transducers are installed, this feature is

 

 

 

 

 

play.

 

ignored. The default value is on. This should be

 

 

 

 

2. Press the Menu button.

 

appropriate for most locations. Use the Left and

 

 

Right Arrow Buttons to make the desired change

 

3. Using the Up and Down arrow buttons, scroll from

 

and then press the Enter button.

 

 

SET PASSWORD to RESET DEFAULTS and press

NOTE: If the FLUSH BY PRESS DIFF option is set

 

 

the Enter button.

to “off,” the system will then display the DEMAND

4.

The system displays the ENTER PASSWORD dis-

SENSOR display which is protected by a special

 

 

play. The default password is AAAA. Use the Up

password. Leave the DEMAND SENSOR option

 

 

and Down arrow buttons to enter the password.

OFF and press the Enter button to go to the

 

 

After each entry, press the Enter button.

PREFLUSH display. For more information on the

 

 

If you enter the wrong password, the system will

DEMAND SENSOR option, contact the manufac-

 

 

 

 

display the ACCESS DENIED. PRESS ‘ENTER’ TO

turer.

 

 

 

 

 

 

CONTINUE message. Press Enter or wait and the

8.

If the FLUSH BY PRESS DIFF setting is set to

 

 

 

 

system will prompt you for the password again.

 

on, the system will then prompt for a pressure

 

 

 

 

differential value. The default value is 21 psi,

 

 

IMPORTANT

 

which should be fine for most locations. To

 

If you cannot remember your password, call

 

change this value, use the Up and Down arrow

 

Technical Service immediately for assistance.

 

buttons to make a change. Then, press the Enter

5.

The system displays the TURN OFF POWER,

 

button.

 

 

WAIT 10 SEC, RESTORE POWER message.

9.

The system displays the PREFLUSH display. The

 

 

Unplug the power cord and wait for ten (10) sec-

 

default value is on. This should suit most loca-

 

 

onds or more, and then plug the cord in again.

 

tions. To change this value, use the Left and

 

6. The system then cycles through initialization

 

Right arrow buttons to select on or off. Press

 

 

displays and prompts you to set the Date and

 

the Enter button to accept the change (or to

 

 

Time. Follow the instructions in the Set Date/Time

 

accept the default value if a change is not made).

 

 

Modes section of this manual. The system can

10.

Regardless of the setting of the PREFLUSH

 

 

then be re-programmed as desired.

 

option, the system then displays the BACKWASH

 

REVIEW OF CYCLES MODE

 

LENGTH prompt. The default for this option is

1.

From the FILTER MODE display, press the Stop

 

00:20 seconds which should be fine for most

 

 

 

button. The system displays the STOP MODE dis-

 

locations. Enter the desired length of time for the

 

 

 

 

 

play.

 

backwash operation in mm:ss format. Press the

 

 

 

Enter button to accept the change (or to accept

 

2. Press the Menu button.

 

the default value if a change is not made).

 

3. Using the Up and Down arrow buttons, scroll to

11.

Next, the system displays the FORWARD FLUSH

 

 

 

REVIEW OF CYCLES. Press the Enter button.

 

LENGTH prompt. Enter the desired length of time

4.

The system displays the REVIEW HISTORY dis-

 

for the forward flush operation in mm:ss format.

 

 

 

play. The default value is off. Use the Left

 

The default value is 00:10 seconds, which should

 

 

 

 

 

and Right arrow buttons to toggle between off

 

be fine for most locations. Press the Enter but-

 

 

 

 

 

and on. With the setting set to on, use the Up

 

ton to accept the change (or to accept the default

 

 

 

 

 

and Down arrow buttons to view a history of

 

value if a change is not made).

 

 

 

 

 

keystrokes with date and time information. This

12.

The system displays the SET FLUSH CYCLE dis-

 

 

 

 

information can be used to determine causes of

 

play. If you need to correct any settings, press

 

 

problems or assist in servicing the system.

 

enter and make the desired changes. If changes

 

 

 

 

are not necessary, press the Menu button to

 

 

 

 

return to the STOP MODE display.

 

 

 

13.

Press the Run button to return to FILTER MODE.

 

 

 

 

 

 

 

P/N 1010852 Rev. C 04/06

13

 

 

Page 13
Image 13
Antunes, AJ SE-4200/4400 WATER FILTRATION SYSTEM, OPERATION continued, NOTE If the FLUSH BY PRESS DIFF option is set