Antunes, AJ SE-4200/4400 owner manual OPERATION continued, Programming, Message, Description

Models: SE-4200/4400

1 24
Download 24 pages 32.42 Kb
Page 11
Image 11
OPERATION (continued)

SE-4200/4400 WATER FILTRATION SYSTEM

OPERATION (continued)

Programming

1.Once the system is connected to a power source, the unit displays the following messages in the table below in order:

 

Message

 

Description

ANTUNES FILTRATION

Shows the software and

Rev. 00.00.00

 

hardware revision informa-

 

tion.

 

 

 

ver-

BASIC ON:lcd

ON

Indicates the system hard-

units- US:audio ON

ware setup.

 

 

 

 

 

BORE

AIR RELEASE

 

Indicates the unit is filling

00:05

mm:ss

 

filters with water.

 

 

 

 

 

STOP MODE

 

Indicates the controller is

00/00/00 00:00:00

AM

performing internal tests to

verify correct filter operation.

 

 

 

FILTER MODE

 

Indicates the unit is in

00/00/00 00:00:00

AM

FILTER MODE.

 

 

 

 

 

Using the Up and Down arrow buttons, enter the correct date in mm/dd/yy format. After each entry, press the Enter button. For example, for June, set the month as 06 and then press the Enter button. Set the date and year in this same manner.

5The system then displays the SET TIME message. Using the Up and Down arrow buttons, enter the correct hour in hh format and press the Enter but- ton. Then, enter the correct minutes in mm format and press the Enter button. Finally, select AM or PM and press the Enter button.

6.After setting the date and time, the system dis- plays the SET DATE/TIME message. If you need to make a correction to your settings, you can press the Enter button and make any changes. If the settings are correct, press the Menu button to return to the STOP MODE function. The correct date and time should be displayed.

After the system displays the FILTER MODE message, proceed to the next step.

NOTE: Only a few items need to be programmed to allow for the proper operation of the system. Default values in the system programming are set to automatically flush the filter cartridges for 1 min- ute every hour. Default values should be sufficient for most locations’ filtration needs.

NOTE: To skip a value, accept a default value, or to save a changed value, you MUST press the Enter button to save the entry and proceed to the next option. If you make a mistake, press the Menu but- ton to go back to the previous display.

SET DATE/TIME MODE

NOTE: The Date and Time must be set in order for proper system operation.

1.If the system does not already display the SET DATE/TIME message, from the FILTER MODE, press the Stop button. The system enters STOP MODE and displays STOP MODE on the display.

2.Press the Menu button.

3.Using the Up and Down arrow buttons, scroll from SET PASSWORD to SET DATE/TIME and press the Enter button.

4.The system displays the SET DATE message.

7.Press the Run button to return to the FILTER MODE function.

SET FILL FUNCTION MODE (BORE AIR RELEASE)

1.From the FILTER MODE display, press the Stop button. The system displays the STOP MODE message.

2.Press the Menu button.

3.Using the Up and Down arrow buttons, scroll from SET PASSWORD to SET FILL FUNCTION. Press the Enter button.

4.The system displays the BORE AIR RELEASE message. The default time is displayed as 00:05 seconds, which should be sufficient for most locations. To change this setting, use the Up and Down arrow buttons and the Enter key to make the change. For example, to change the setting to six, press the Enter button until the cur- sor is in the fourth position and use the Up/Down arrow buttons to change the setting to the desired time.

5.Next, the system displays the SET FILL FUNCTION display. If you need to make a cor- rection to the Fill Function setting, press the Enter button to do so. If the setting is correct, Press the Menu button to save the setting and return to

STOP MODE.

6.Press the Run button to return to FILTER MODE.