Manuals
/
APC
/
Household Appliance
/
Air Conditioner
APC
ACPCW40-150, ACPDX21-86 manual
Models:
ACPCW40-150
ACPDX21-86
1
91
92
92
Download
92 pages
27.88 Kb
85
86
87
88
89
90
91
92
<
>
Specs
Install
Warranty
Dimension
InRoom Cooling Unit Configurations
Alarms
Temperature and Humidity Design Conditions
Weight
American Power Conversion Legal Disclaimer
Standard Features
Page 91
Image 91
Page 90
Page 92
Page 91
Image 91
Page 90
Page 92
Contents
Precision Air Conditioner
Technical Data
InRoom
ACPDX21-86, ACPCW40-150
American Power Conversion Legal Disclaimer
General Specifications
Contents
60Hz Performance Specifications
50Hz Performance Specifications
InRoom Nomenclature
General
Overview
APC InRoom The Right Solution
Scalable Solution for Critical Environments
Temperature and Humidity Design Conditions
High & Low Temperature
Standard Features
Optional Features
ACAC76106
Weight Kg Lb Ea
Model #
ACAC75107
Depth
Upflow discharge plenums
Cabinet size
Width
Width
Unit Sub Base Plenum with no Grills
Unit Sub Base Plenum with Grills
Cabinet size
Width
Cabinet
Model
Height
Width
Cabinet
Model
Height
Width
Cabinet
Model
Height
InRoom Precision AC Tech Data Manual
Condensers
InRoom Standard Condensers - 60 Hz
InRoom Low Temperature -30ºFCondensers - 60 Hz
InRoom High Temperature Condensers - 60 Hz
50 Hz
InRoom Condensers - 50 Hz
A B H
at 20C 68F
InRoom Receivers - 50 Hz
50 Hz
Control Type
Display Interface
Alarms
Logging
InRoom Chilled Water Model Sizes
InRoom Model Sizes
InRoom Direct Expansion Model Sizes
Cabinet Size
Fluid Cooled Glycol
InRoom Cooling Unit Configurations
Chilled Water
Air Cooled DX
PCW400
60Hz Performance Specifications
Chilled Water CW – 60Hz
Chilled Water
PCW900
Chilled Water Continued
PCW400
PCW660
PA311
Air Cooled DX System – 60Hz
Air Cooled
PA211
PA452 Cabinet Size
Air Cooled DX Continued
PA211 Cabinet Size
PA311 Cabinet Size
PACW311
MultiCool – Air Cooled DX with CW – 60Hz
Net Cooling Capacity
PACW211
PACW452
Net Cooling Capacity - 7.2C 45F EWT
PACW211
PACW311
PACW452
Information common to both modes
PACW211
PACW311
PG311
Fluid Cooled Glycol 40% - 60Hz
Net Cooling Capacity
PG211
PG452
Fluid Cooled Glycol 40% Continued
PG211
PG311
PG311
Fluid Cooled Glycol 0% – 60Hz
Net Cooling Capacity
PG211
PG452
Fluid Cooled Glycol 0% Continued
PG211
PG311
PGCW311
Fluid Cooled Glycol 0% with CW – 60Hz
Net Cooling Capacity
PGCW211
PGCW452
Net Cooling Capacity -7.2C45F EWT
PGCW211
PGCW311
PGCW452
Information common to both modes
PGCW211
PGCW311
PGCW311
Fluid Cooled Glycol 40% with CW - 60Hz
Net Cooling Capacity
PGCW211
PGCW452
Net Cooling Capacity -7.2C45F EWT
PGCW211
PGCW311
PGCW452
Information common to both modes
PGCW211
PGCW311
PGE311
Fluid Cooled Glycol 40% with Economizer - 60Hz
Net Cooling Capacity
PGE211
PGE452
Net Cooling Capacity
PGE211
PGE311
PGE612 Cabinet Size
Information common to both modes
InRoom Precision AC Tech Data Manual
Compressor
60Hz InRoom Electrical Specifications
With Reheat and
Without Reheat and
Chilled Water CW Electrical Data
PCW400
50Hz Performance Specifications
Chilled Water CW - 50Hz
Net Cooling Capacity
PCW900 Cabinet Size
Chilled Water Continued
PCW400 Cabinet Size
PCW660 Cabinet Size
PA311
Air Cooled DX System - 50Hz
Net Cooling Capacity
PA211
PA452
Air Cooled Continued
PA211
PA311
PACW311
MultiCool - Air Cooled DX with CW - 50Hz
Net Cooling Capacity
PACW211
PACW452
Net Cooling Capacity - 7.2C 45F EWT
PACW211
PACW311
PACW452
Information common to both modes
PACW211
PACW311
PG311
Fluid Cooling Glycol 40% – 50Hz
Net Cooling Capacity - 40.5C 105F EWT
PG211
PG452
Fluid Cooled Glycol 40% Continued
PG211
PG311
PG311
Fluid Cooled Glycol 0% – 50Hz
Net Cooling Capacity
PG211
PG452
Fluid Cooled Glycol 0% Continued
PG211
PG311
PGCW311
Fluid Cooled Glycol 40% with CW - 50Hz
Net Cooling Capacity
PGCW211
PGCW452
Net Cooling Capacity - 7.2C 45F EWT
PGCW211
PGCW311
PGCW452
Information common to both modes
PGCW211
PGCW311
PGE311
Fluid Cooled Glycol 40% with Economizer - 50Hz
Net Cooling Capacity
PGE211
PGE452 Cabinet Size
Net Cooling Capacity
PGE211 Cabinet Size
PGE311 Cabinet Size
PGE452
Information common to both modes
PGE211
PGE311
50Hz InRoom Electrical Specifications
Technical Specifications
General Specifications
Storage
Transporting and Storage
Delivery of the unit
Moving the unit
Room preparation
Guidelines for Installation
Service access
Power to the unit
InRoom Precision AC Tech Data Manual
Illustration Number
Airflow Direction
Cabinet Size
PCW400
Piping Connections
Downflow Chilled Water Cooling Units
Model
View from the bottom of the unit
View from the bottom of the unit
Dimensions are in mm in
Power wire inlet, 10 mm 0.375 in pilot hole
Control wire inlet, 10 mm 0.375 in pilot hole
View from the bottom of the unit
na2851a
InRoom Precision AC Tech Data Manual
PCW660
Upflow Chilled Water Cooling Units
Model
PCW400
PA612
PA211
PA311
PA452
1.02DESIGN REQUIREMENTS
InRoom Guide Specifications
1.05WARRANTY
PART 1 GENERAL 1.01SUMMARY
C.REFRIGERATION COMPONENTS
PART 2 PRODUCT 2.01STANDARD COMPONENTS
A.CABINET CONSTRUCTION
B.ELECTRONICALLY COMMUTATED EC FANS
D.CONTROLLER
G.FILTERS 30%
J.MAIN POWER DISCONNECT
E.ELECTRICAL PANEL
F.EVAPORATOR COIL/CONDENSATE PAN
N. ADDITIONAL PROGRAMMABLE INPUT/OUTPUT I/O
C.SMOKE DETECTOR
F.FLOW SWITCH
2.02OPTIONAL COMPONENTS A.FLOORSTAND
B.PLENUM
H.SECONDARY POWER SUPPLY
3.02CONDENSER
PART 3 INDIVIDUAL SYSTEMS 3.01AIR-COOLED
InRoom Precision AC Tech Data Manual
3.06ECONOMIZER
3.03WATER-COOLED
3.04GLYCOL-COOLED
3.05PUMP PACKAGE
InRoom Precision AC Tech Data Manual
3.09FLUID COOLER
Non-transferablewarranty
Warranty
One-YearFactory Warranty
Terms of warranty
InRoom Precision AC Tech Data Manual
Warranty claims
Parts
Warranty Procedures Claims
Page
990-3299A-001
APC Worldwide Customer Support
9/2009