E.g., user chooses RAID 5 and the controller has 12*200G HDD + 4*80HDD inserted. Then if using all 16 HDD for a RAID 5, then the volume max size is 1200G (80G*15). But in IS16GL, we do smarter check and find out the most efficient use of HDDs, which results controller only use the 200G HDD (Volume size is 200*11=2200G). Then, the volume size is bigger, and full use of HDD capacity.

Step 1: Select “Quick install” then choose the RAID level to set. Please refer to

Figure 3.3.1. After choosing the RAID level, click “Manual background”, which links to another page, user can set up “LUN” here.

Figure 3.3.1

Step 2: Please select a LUN number. Access control of host would show as a wildcard “*”, which means every host can access this volume. In this page, the “Volume size” can be changed. The maximum volume size is shown. To re-enter the size be sure it has to be less or equal to maximum volume size. Then click

Manual background”.

Step 3: Confirm page. Click “Manual background” if all setups are correct. Then a page with the “User data volume” just been created will be shown as Figure 3.3.2.