CHECK DUAL HANDLE
INTERLOCK
Without the engine running, press down (engage) both clutch levers. Release attachment clutch lever. Attachment clutch should remain engaged until traction clutch lever is released, then both clutches must disengage.
CHECK FASTENERS
Make sure all hardware is tightened properly.
CHECK CLUTCHES
Auger / impeller must stop within 5 seconds when attachment clutch/impeller brake lever is released.
Wheels must stop quickly when traction drive clutch lever is released.
If clutches do not engage or disengage properly, adjust or repair before operation (see Service and Adjustments).
CLEAN ENGINE
Refer to Engine Manual for detailed instructions.
CHECK ENGINE OIL
The engine crankcase oil should be checked every 5 hours of operation. Oil level MUST be maintained in safe operating range on dipstick at all times or engine damage will result (See Engine Manual).
Park unit on a level surface. Refer to Engine Manual for detailed instructions.
CHANGE ENGINE OIL
Change oil after first 2 hours of operation, thereafter change oil every 25 hours (more often if required). Refer to Engine Manual for detailed instructions.
Run engine just prior to changing oil. Warm oil will flow more freely and carry away more contamination. Remove the oil drain plug from the rear of the unit and tip the unit back to help drain all the oil.
CHECK TIRE PRESSURE
Keep tires at pressure listed on the tire sidewall.
CHECK AUGER GEARCASE
IMPORTANT: Proper oil level must be maintained.
Gear cases are filled to the correct level at the factory. Unless there is evidence of leakage, no additional lubricant should be required. Check oil level each season or every 25 hours of operation.
To ensure adequate lubricant level:
1.Remove filler plug (Figure 14). Lubricant must be at least up to bottom of lubricant filler hole with unit resting on a
2.Add lubricant if required. Allow oil to drain to level of plug and replace plug.
IMPORTANT: Use only Ariens special gear lubricant
1
3
2
1.Auger Gearcase - Cast Iron
2.Oil Fill and Drain Plug
3.Auger Gearcase - Aluminum
Figure 14
GENERAL LUBRICATION
IMPORTANT: Wipe each fitting clean before and after lubrication.
IMPORTANT: DO NOT allow grease or oil to get on friction disc, friction plate or belts.
NOTE: Apply Stens Mix
Auger Shaft
NOTE: To grease auger shaft, remove shear bolt nuts, and shear bolts. Turn auger on shaft while applying grease at zerk fittings. Replace shear bolt per instructions in Service and Adjustments.
GB - 20