Troubleshooting

Table A-1 describes how to troubleshoot problems with your network and/or the Switch by monitoring the Switch’s LEDs.

Table A-1 Troubleshooting

Problem

Indication

Action

 

 

 

No Power

Power LED OFF

Check the power cord.

 

 

Make sure the power outlet is functional.

 

 

Make sure the power cord is properly connected to

 

 

the outlet and is securely connected to the hub.

 

 

 

Port connection

Link Activity LED

Make sure the cable is functioning and is properly

not functioning

OFF

connected at both ends.

 

 

Check the crimp of the RJ-45 connectors.

 

 

Make sure the UTP cable is Category 5 for

 

 

100Base-TX.

 

 

Make sure the UTP cable is Category 3 for

 

 

10Base-T.

 

 

Make sure the cable length does not exceed 100

 

 

meters.

 

 

 

Hub ID incor-

No HUB ID LED

Check with Asanté technical support.

rect

lit, or same HUB

 

 

ID LED lit on two

 

 

hubs

 

 

 

 