III.INSTALLATION
11.Chassis , CPU , & Power Supply Fan ConnectorsThese connectors support cooling fans of 500mAMP (6WATT) or less. Orien- tate the fans so that the heat sink fins allow airflow to go across the onboard heat sink(s) instead of the expansion slots. Depending on the fan manufacturer, the wiring and plug may be different. The red wire should be positive, while the black should be ground. Connect the fan’s plug to the board taking into consid- eration the polarity of the this connector. NOTE: The “Rotation” signal is to be used only by a specially designed fan with rotation signal.
WARNING! The CPU and/or motherboard will overheat if there is no airflow across the CPU and onboard heatsinks. Damage may occur to the motherboard and/or the CPU fan if these pins are incorrectly used. These are not jumpers,
do not place jumper caps over these pins.Chassis Fan Power
CPU Fan Power
Power Supply Fan
| Rotation +12V GND | Air Flow | Air Flow | ||||||||||
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Orientate the fins so that air flow
runs across motherboard's regulators.
12Volt Cooling Fan Power
12.Chassis Open Alarm LeadThis lead is for an open chassis monitor. A high level signal to the chassis signal lead will indicate to the system that the chassis has been opened. For the chassis open alarm feature to work, you must have the LM78 hardware monitor (op- tional) onboard and connect a sensor or switch to the connector. The +5V power
comes from the power supply, when the A/C is connected.INSTALLATION | Connectors |
III. |
|
|
|
Power supply standby +5V
Ground
Chassis Signal
Chassis Open Alarm Lead
ASUS | 29 |