2.8.3Replacing optical drive (optional)

This server system supports a slim-type optical disk drive. Follow the steps below to replace the optical disk drive.

1.Remove the screw that secures the optical drive. Keep the screw for reassembly.

2.Remove the SATAII/SAS drive tray by pushing the spring lock to the right, then pulling the tray lever outward. The drive tray ejects slightly after you pull out the lever.

3.Firmly hold the tray lever and pull the drive tray out of the bay.

4.Pull the optical drive module.

5.Carefully insert the replacement optical disk drive module into the drive bay until it is securely seated in place.

6.Carefully insert the drive tray and push it all the way to the depth of the bay until just a small fraction of the tray edge protrudes.

7.Push the tray lever until it clicks, and secures the drive tray in place. The drive tray is correctly placed when its front edge aligns with the bay edge.

8.Secure the optical drive with the

screw that you removed in step 1.

2-22

Chapter 2: Hardware setup