AT&T MLS-12DTM, MLS-12TM, MLS-6TM Specifications, Processor/206 modules, 11“D x 17H x 1.5”Wor

Models: MLS-12D

1 87
Download 87 pages 60.77 Kb
Page 11
Image 11
Specifications

Specifications

A

Table 1-1 Technical and Environmental Specifications

Capacities

System

 

 

 

206 Module

Extension Jack

8 outside lines via line jacks on

2 outside lines

Maximum 2 devices per exten-

 

four 206 modules

 

6 extensions

sion jack, total REN on jack not

24 extensions via extension jacks

 

to exceed 2* (2 devices require

 

on four 206 modules

 

 

AT&T 267F2 bridging adapter)

1 loudspeaker paging system via

 

No more than one PARTNER

 

PAGE jack on processor module

 

phone per jack.

1 audio source via MUSIC ON

 

A PARTNER display

 

HOLD jack on processor module

 

 

 

phone must be connected

2 doorphones, using 2 extension

 

 

to Extension 10.

 

jacks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

Processor/206 modules

11“(D) x 17"(H) x 1.5”(W)or

4.3cm x 6.6cm x .58cm

 

Control

unit

12”(D) x 19"(H) x 11“(W)or 4.7cm x 6.8cm x 4.3cm (assembled)

 

PARTNER

telephones

9.5”(D) x 5"(H) x 6.75”(W) or 3.7cm x 1.9cm x 2.6cm (assembled)

 

 

 

 

 

Weights

Processor

module

4.0 lbs or 8.8 kgs

 

(approx.)

206 module

4.5 Ibs or 9.9 kgs

 

 

Backplane & cover

5.5 Ibs or 12.2 kgs

 

 

MLS-6

telephone

1.8 lbs or 4.0 kgs

 

 

MLS-12

telephone

2.0 Ibs or 4.4 kgs

 

 

MLS-12D telephone

2.1 Ibs or 4.6 kgs

 

 

 

 

 

 

 

Switch Fabric

Full digital,

nonblocking

 

 

 

 

 

 

 

Electrical

2 amps at full system capacity

 

 

Specifications

200 watts at full system capacity

 

 

 

4-day memory backup (96 hours)

 

 

 

Dissipation of power (65 watts during normal operation)

 

 

684 BTUs/hour at peak; 225 BTUs/hr at normal

 

 

 

Extension Jack

Ringing voltage: +5VDC, -140 VDC peak to peak; Trapezoidal wave shaping

Specifications

48-volt talk battery

 

 

 

 

Ringing frequency: 20 Hz

 

 

 

 

 

Environmental

Mount on a wall or sturdy, level surface at least 2 feet (.6 meters) from the floor (wall mount-

Requirements—

ing strongly recommended)

 

 

 

Control Unit

Locate within 5 feet (1.5 meters) of an electrical outlet not controlled by a switch and within

5 feet (1.5 meters) of the network interface jacks, when using supplied 7- (2.1-meter) cords

o

Operating temperature 32° to +I04°F (0° to +40C), not in direct sunlight Humidity 15%-90%, noncondensing

For proper ventilation and easy replacement of modules, provide at least 6“ (2.34cm) clear- ance at the top and sides and 1 foot (0.3 meters) at the front of the control unit.

Locate in an area free of excess moisture, corrosive gases, dust, and chemicals

*The two devices combined on an extension jack can be a PARTNER phone with a standard device, or two standard devices; DO NOT connect two PARTNER phones to the same extension jack. If a device lists two RENs, use the higher number when adding up RENs.

1-4 System Components and Specifications

Page 11
Image 11
AT&T MLS-12DTM, MLS-12TM, MLS-6TM Processor/206 modules, 11“D x 17H x 1.5”Wor, System Components and Specifications