AT&T MLS-12DTM, MLS-6TM Recall Timer Duration, Recall Timer 18 450-msec, Recall Timer 16 400-msec

Models: MLS-12D

1 87
Download 87 pages 60.77 Kb
Page 28
Image 28
Recall Timer

Recall Timer

Duration

Code: #107

Description: Changes the length of the timed signal (a switchhook flash) exe- cuted by the Recall feature (p. 4-8) and by the Recall function of speed dialing (p. 3-36). Recall sends this timed signal over the phone line to the local tele- phone company or PBX/Centrex to which the system is connected. Typically you use the Recall feature to access PBX or Centrex features such as Call Waiting.

Change the factory setting of the recall timer only under three conditions:

If your PARTNER Plus system is connected to Centrex, set the recall timer to 800 milliseconds (msec) by entering [ 3 ] [ 2 ].

If your PARTNER Plus system is connected to a PBX or Centrex and Recall drops calls, shorten the time.

If pressing Recall has no effect, lengthen the time.

Valid Entries: 01 through 80 (25 to 2000 msec in 25 msec increments)

18 (450 msec)

Programming Steps:

1.Press [ Feature ] [ 0 ] [ 0 ] [ System Program ] [ System Program ] [ # ] [ 1 ] [ 0 ] [ 7 ] . The display reads:

Recall Timer

18450-msec

2.Enter a different recall timer setting by pressing [ Next Data ] or [ Prev Data ]. For example, to shorten the recaIl timer to 400 msec, press [ Prev Data ] twice.

The display reads:

Recall Timer

16 400-msec

Or enter the setting number directly. For example, to set the recall timer to 800 msec, press [ 3 ] [ 2 ].

3.If you are using Recall to access PBX or Centrex features, test the new Recall Timer Duration by trying to use these features:

If the call is disconnected, shorten the time.

If the Recall signal has no effect, lengthen the time.

= Factory Setting

 

To go to the next procedure: [Next Proc ]

To go to a specific procedure: [# ] [ x ] [ x ] [ x ] [ x ]

 

 

 

 

 

(where XX X is the procedure number)

 

To go to the previous procedure: [ Prev Proc ]

 

 

 

To return data to the factory setting: Remove[

] To exit system programming: [ Feature ] [ 0 ] [ 0 ]

System Programming 3-7

Page 28
Image 28
AT&T MLS-12DTM, MLS-12TM, MLS-6TM manual Recall Timer Duration, Recall Timer 18 450-msec, Recall Timer 16 400-msec