ATTO Technology 463-248-202 manual System

Models: 463-248-202

1 48
Download 48 pages 53.09 Kb
Page 11
Image 11
System 25

Table 1-1. PagePac Plus Connectivity Chart (Continuation Page 1)

 

 

 

 

System 25

 

 

 

System 75/G1/G3I Definity

 

System 85/G2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

C.O. Line

Analog

 

Aux.

 

C.O.

Analog

 

Aux. Port

 

C.O.

Analog

 

Aux.

 

 

 

 

 

Station

 

P o r t

 

Line

Station

 

 

 

 

Line

Station

 

Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop

 

Yes

 

 

 

 

Yes

 

 

Yes

 

 

 

Start

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

Yes

 

 

 

 

Yes

 

 

Yes

 

 

 

Start 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

 

 

 

 

 

 

 

 

Loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(HI Z)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

 

 

 

 

Yes

 

 

 

 

 

 

Yes

 

 

 

 

 

 

Yes

 

 

Loop

 

 

 

 

 

Note 2

 

 

 

 

 

 

Note 2

 

 

 

 

 

 

Note 2

 

 

(600 Ω)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

— Indicates a non applicable connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comkey 416, 718

 

 

 

 

H o r i z o n

 

 

 

 

D i m e n s i o n

 

 

 

 

 

1434

and 2152

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

C.O. Line

Intercom

 

C.O. Line

Analog

 

Intercom

 

C.O. Line

 

Analog

 

Aux.

 

 

 

 

 

 

 

 

 

 

 

 

Station

 

 

 

 

 

 

 

Station

 

Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop

 

Yes

 

 

Yes

 

 

 

 

 

 

Yes

 

 

 

 

Start

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

 

 

Yes

 

 

 

 

 

 

Yes

 

 

 

 

Start 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

 

 

 

Yes

 

 

 

 

 

Yes

 

 

 

Loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(HI Z)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

No

 

 

 

 

 

No

 

 

 

 

Yes

 

 

Loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 2

 

 

(600 Ω)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.Two pound keys (##) must be pressed for one pound key (#) to be sent to the AmpliCenter when dialing from a multi-button set.

2.A 2 pair RJ-11 cord must be used to interface with the AmpliCenter.

3.Ground Start trunk for tel. system must share a common ground with AmpliCenter page input ground.