Installation (for qualified installers only) | 13 |
Optional Gas Line Location
a
Remove the two screws near the
gas inlet (save these screws).
Remove the cover plate on the bottom b of the fireplace (save these nuts).
Phillips
Screwdriver
HINT: remove the control cover for easier access.
5/16" Wrench
c
Position the gas inlet assembly over the hole in
the baseplate (do not secure at this time). Position the cover plate over the gas inlet hole on the left side of the fireplace and secure using the nuts removed in step “b”.
d Secure the gas inlet assembly using the screws removed in step “a”.
Phillips
Screwdriver
Electrical Connection
•Make sure the household breaker is shut off prior to working on any electrical lines.
•The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA
•The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)
Electrical Line Location
Standard Location
Optional Location
The optional electrical inlet is flush with the base of the fireplace.
7"
NOTE: a
© Travis Industries | 4040830 |