Installation (for qualified installers only) | 9 |
Fireplace Placement Requirements
Minimum Framing Dimensions
The fireplace requires a 1/2" space between the fireplace and the framing members (or other materials) along the sides and back of the fireplace. The
48" Min.
The fireplace enclosure must be a minimum 48" above the base of the fireplace. NOTE: Do not build into the area above the fireplace (except for the required framing members).
HINT: We recommend installing the shaded framing after the fireplace is in place.
Thermostat or Remote
Control Wire (either side)
WARNING: A
Firestop
(required)
36"
1/2" Clearance to the front, 0" to the sides, 1" below, and 2" above the vent to combustibles.
If using an elbow directly off the fireplace, the vent will be centered
HINT: we recommend reinforcing the upper corners of the fireplace opening.
6"
1"
5"
Route the electrical line to a position to the right rear of the fireplace.
•Fireplace must be installed on a level surface capable of supporting the fireplace and vent
•Fireplace must be placed directly on wood or
•This heater may be placed in a bedroom. appliance produces when determining a
Please be aware of the large amount of heat this location.
Clearances
•When installed, walls in front of the fireplace must be a minimum 1" to the side of the faceplate.
•Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies.
•Fireplace must be placed so the vents below and above the glass do not become blocked
© Travis Industries | 4040830 |