34 | Finalizing the Installation |
8.Replace the glass.
9.Attach the face following the directions below (see the directions included with the face for full details).
Face Installation and Removal
The face has hooks that hold it in place. Make sure the face locks in place when installing.
PLATED SURFACES:
Make sure the plated surfaces are clean before starting the fireplace. Any marks left on plated surfaces may become etched in place. Clean plated surfaces with denatured alcohol and a soft cloth.
b
Lift and rotate the face forward until the top brackets lock into the upper slots.
a |
Tilt the face back and insert the bottom brackets into the lower slots until they lock in place.
The bottom of the face is
ACID WASH WARNING: Before installing the faceplate, make sure any masonry that has been treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash (muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia solution, the gold face may develop a permanent tarnish when the acid evaporates over time. Contact your dealer if uncertain your facing has been properly neutralized.
10.Turn the flame adjust knob to its highest position - the flames should be approximately 10" tall. Check the flame on low position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your dealer for a remedy.
11.Give this manual to the home owner and fully explain the operation of this heater.
© Travis Industries | 4040830 |