5.7. Configure SIP Endpoint

This section describes the steps for administering OPS stations in Communication Manager and associating the OPS station extensions with the telephone numbers of SpectraLink 8400 Series. Enter add station s, where s is an extension valid in the provisioned dial plan. The following fields were configured for the compliance test.

Type – Set to 9630SIP.

Name – Enter a descriptive name

Repeat this step as necessary to configure additional SIP endpoint extensions.

Add station 28002

Page

1 of 6

 

 

 

 

 

STATION

 

 

Extension: 28002

Lock Messages? n

BCC: 0

 

 

Type: 9630SIP

 

Security Code:

TN: 1

 

Port: S30168

 

Coverage Path 1: 99

COR: 1

 

 

Name: WiFi-1

 

Coverage Path 2:

COS: 1

 

 

 

 

 

Hunt-to Station:

 

 

STATION OPTIONS

 

 

 

 

 

 

 

Time of Day Lock Table:

 

 

 

Loss Group: 19

 

 

 

 

 

 

 

Message Lamp Ext: 28002

 

 

Display Language: english

Button Modules: 0

 

 

 

Survivable COR: internal

 

 

 

Survivable Trunk Dest? y

IP SoftPhone? n

 

 

 

 

 

 

 

 

 

On Page 6 of the STATION form, enter the trunk group number that was assigned in Section 5.6 for the SIP Trunk field.

add

station

28002

 

 

Page

6 of 6

 

 

 

 

 

STATION

 

SIP

FEATURE

OPTIONS

 

 

 

Type of 3PCC Enabled: None

 

 

 

 

 

SIP Trunk: 201

 

 

 

Enter the add off-pbx-telephonestation-mappingcommand and configure the following:

Station Extension – Set the extension of the OPS station as configured above.

Application – Set to OPS.

Phone Number – Enter the number that SpectraLink 8400 Series will use for registration and call termination. In the example below, the Phone Number is the same as the Station Extension, but is not required to be the same.

Trunk Selection – Set to the trunk group number configured in Section 5.6.

Config Set – Set to 1

Repeat this step as necessary to configure additional off-pbx-telephone station-mapping.

 

add off-pbx-telephone station-mapping

28003

 

Page

1

of 3

 

 

 

STATIONS

WITH OFF-PBX TELEPHONE INTEGRATION

 

 

 

 

 

Station

Application

Dial CC

Phone Number

Trunk

Config

Dual

 

Extension

 

Prefix

 

Selection

Set

 

Mode

 

 

28002

OPS

-

28002

201

1

 

 

 

 

CRK; Reviewed:

Solution & Interoperability Test Lab Application Notes

 

 

 

11 of 21

 

SPOC 7/1/2011

 

©2011 Avaya Inc. All Rights Reserved.

 

 

 

Polycom8400-SES

Page 11
Image 11
Avaya 8400-SES manual Configure SIP Endpoint, ∙ Type Set to 9630SIP, ∙ Application Set to OPS, ∙ Config Set Set to