44AXIS 210/210A/211/211A - System Options

44AXIS 210/210A/211/211A - System Options

Network - UPnP™

The cameras includes support for UPnP, which is enabled by default. If also enabled on your computer, the camera will automatically be detected and a new icon will be added to “My Network Places.”

Note: UPnP must also be enabled on your Windows XP or ME computer. To do this, open the Control Panel from

the Start Menu and select Add/Remove Programs. Select Add/Remove Windows Components and open the Networking Services section. Click Details and then select UPnP as the service to add.

Network - RTP / MPEG-4

These settings are for the IP addresses, port numbers, and Time-To-Live values to use for media streams in the MPEG-4 format. Only certain IP addresses and port numbers should be used for these streams. For more information, please see the online help.

Ports & Devices

I/O Ports - the pinout, interface support and the control and monitoring functions provided by this connector are described in The I/O Terminal Connector, on page 47.

LED Settings

The Status indicator LED on the front of the camera can be set to flash at a configurable interval (or to not light up at all) whenever the unit is accessed. For a listing of all LED behavior, see page 8, or the online help.

Note: The LED does not flash when the stream is retrieved using MPEG-4 multicast.

Maintenance

Restart - The camera is restarted without changing any of the settings. Use this method if the unit is not behaving as expected.

Restore - The unit is restarted and most current settings are reset to factory default val- ues. The settings that will not be reset are as follows:

the boot protocol (DHCP or static)

the static IP address

the default router

the subnet mask

the system time

Default - The default button should be used with caution. Pressing this will return all of the camera's settings (including the IP address) to the factory default values.

Upgrade Server - See Upgrading the Firmware, on page 54.