52AXIS 233D - I/O terminal Connectors
I/O terminal Connectors
The AXIS 233D Network Dome Camera has 3 (8 pin) connectors. The inputs/outputs are used in applications for, e.g. event triggering, time lapse recording, alarm notification via email, picture storage to FTP locations.
Power/Audio
Outputs
Network connector
Inputs
•Power, auxiliary power, GND and audio.
•4 solid state relay outputs - These can drive a maximum load of 50V DC at 500mA directly or heavier loads by connecting additional relay circuitry. If the output is used with an external relay, a diode must be connected in parallel with the load for protection against voltage transients.
•4 alarm inputs - Used for connecting external alarm devices and triggering images for specific