54AXIS 233D - I/O terminal Connectors
I/O terminal connector blocks
Pin |
| Function | Description |
|
|
| |
Power/Audio |
| ||
|
|
|
|
1 |
| Power AC | 18 - 30 VAC max 25VA power consumption. |
|
|
|
|
2 |
| Power | 18 - 30 VAC max 25VA power consumption. |
|
| AC/DC+ | |
|
|
| 22 - 40 VDC max 20W power consumption. |
|
|
|
|
3 |
| GND | Ground |
|
|
|
|
4 |
| Vout | 12V/200mA |
|
|
| Vout can be used to power auxiliary equipment, |
|
|
| max 200mA. |
|
|
|
|
5 |
| GND | Ground |
|
|
|
|
6 |
| Line OUT | Mono audio output (line level), which can be connected |
|
|
| to an active speaker with |
|
|
|
|
7 |
| GND | Ground |
|
|
|
|
8 |
| Mic/Line IN | Input for a mono microphone or line level mono signal. |
|
|
| |
Output |
| ||
|
|
|
|
1 |
| Out1_1_relay | On the external device output terminals (e.g. Out1_1 and |
|
|
| Out1_2) there is no distinction between positive and neg- |
2 |
| Out1_2_relay | |
|
|
| ative. The terminals use a photocoupler and are electri- |
3 |
| Out2_1_relay | |
| cally isolated from the other internal circuitry. | ||
|
|
| |
4 |
| Out2_2_relay | |
|
| ||
|
|
|
|
5 |
| Out3_1_relay | The maximum load should not exceed 500mA and the |
|
|
| |
6 |
| Out3_2_relay | maximum voltage should be not more than 50V DC. |
|
|
| Note: Connecting AC to the Output will damage the unit. |
7 |
| Out4_1_relay | |
|
|
|
|
8 |
| Out4_2_relay |
|
|
|
|
|
Input |
|
|
|
|
|
|
|
1 |
| In1_anode(+) | Electrically isolated from the chassis and connectors, |
|
|
| these inputs can be supplied from an external DC voltage |
2 |
| ||
|
|
| or pin 4 (Vout) of the Power/Audio Connector and GND. |
3 |
| In2_anode(+) | |
| (3.3 - 40VDC allowed on the inputs) | ||
|
|
| |
4 |
| ||
| The terminals use a photocoupler and are electrically iso- | ||
|
|
| |
5 |
| In3_anode(+) | lated from the other internal circuitry. |
|
|
| |
6 |
|
| |
|
|
| Note: There is a distinction between anode and cathode |
7 |
| In4_anode(+) | |
|
|
| when making connections! |
8 |
| ||
|
| ||
|
|
|
|