VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS
SPECIFICATIONS
Body Pattern: Straight through; see Table 1 for inlet and outlet size.
Electrical Ratings:
Voltage and Frequency: 24 Vac, 60 Hz.
Current Draw: 0.5A with both operators energized.
Capacity: See Table 1.
Conversion:
Use conversion factors in Table 2 to convert capacities for other gases.
Regulation Range: See Table 1.
Pipe Adapters:
Angle and straight adapters available for
Approvals:
American Gas Association Design Certificate: L2025006.
Canadian Gas Association Design Certificate: L2025006.
Australian Gas Association Design Certificate: 4214. Approved for Delta C applications.
European Community (CE) Certificate: Pending.
PLANNING THE INSTALLATION
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury, or death.
Follow these warnings exactly:
1.Plan the installation as outlined below.
2.Plan for frequent maintenance as described in the Maintenance section.
Heavy demands are made on the controls when direct ignition systems are used on central heating equipment in barns, greenhouses, and commercial properties and on heating appliances such as commercial cookers, agricultural equipment, industrial heating equipment and pool heaters.
Special steps may be required to prevent nuisance shutdowns and control failure due to frequent cycling, severe environmental conditions related to moisture, corrosive chemicals, dust or excessive heat. These applications require Honeywell Home and Building Control Engineering review; contact your Honeywell Sales Representative for assistance.
Review the following conditions that can apply to your specific installation and follow the precautions suggested.
Frequent Cycling
This control is designed for use on appliances that typically cycle three to four times an hour only during the heating season. In
Table 4. Natural-LP Gas Conversion Kits
Model No. Suffix Letter |
| Kit to Convert Natural Gas to LP | Kit to Convert LP to Natural Gas | ||
H, K, M |
| 393691 |
| 394588 |
|
P |
| Not field convertible. |
| Not field convertible. | |
|
|
|
|
|
|
Q |
| 396021 |
| 396025 |
|
|
|
|
|
|
|
R |
| Not required, convertible valve. | Not required, convertible valve. | ||
|
|
|
|
|
|
|
| Table 5. Flange Adapter Part Numbers. |
| ||
|
|
|
|
|
|
Inlet/Outlet |
|
|
| Part No.a,b | |
Pipe Size (in. NPT) |
| Flange Type | Without Hex Wrench | With Hex Wrench | |
3/8 | Straight |
| |||
|
|
|
|
| |
3/8 | Elbow |
| |||
|
|
|
|
| |
1/2 | Straight |
| |||
|
|
|
|
| |
1/2 | Elbow |
| |||
|
|
|
|
| |
3/4 | Straight |
| |||
|
|
|
|
| |
3/4 | Elbow |
| |||
|
|
|
|
|
|
aFlange kits include one flange, one
bDo not use flanges on control models with 3/4 in. inlet and 3/4 in. outlet. On models with 1/2 in. inlet and 3/4 in. outlet, use flanges only on the 1/2 in. inlet side.
2 |