VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS
CAUTION
Equipment Damage.
Can burn out valve coil terminals.
Never apply a jumper across (or short) the valve coil terminals, even temporarily.
Follow the appliance manufacturers instructions if available; otherwise use these instructions as a guide.
IMPORTANT
These gas controls are shipped with protective seals over the inlet and outlet tappings. Do not remove the seals until ready to install adapters or connect the piping.
A | T | N |
| ||
N |
| |
| T | A |
|
|
PRESSURE
REGULATOR
CAP
A | T |
|
| N | |
N |
| |
| T | A |
OR
L | P |
|
| L | |
| P | |
|
|
OTHER SIDE OF CAP
M11678
Converting Gas Control from Natural Gas to LP Gas (or LP Gas to Natural Gas)
WARNING
Fire Or Explosion Hazard.
Can cause property damage, severe injury or death.
1.Do not attempt to convert
2.Always change the main and pilot burner orifices when converting from natural to LP gas or from LP to natural gas. Carefully follow appliance manufacturer specifications and instructions to assure proper appliance conversion.
3.Gas controls are
use a gas control set for natural (manufactured) gas on LP gas, or a gas control set for LP gas on natural (manufactured) gas.
Controls with standard,
Convertible Pressure Regulators
Controls with suffix letter R are convertible pressure regulator models. They can be converted from natural gas to LP gas or from LP gas to natural gas without a conversion kit.
Before converting the control from one gas to another, check the control label and the appliance manufacturer’s rating plate to determine if the pressure regulator setting (factory set) will meet the appliance manifold requirements after conversion.
NOTE: Convertible pressure regulator models (suffix letter R) do not have
If the factory pressure regulator setting meets the appliance manifold requirement, convert the control as follows:
1.Remove the pressure regulator cap, Fig. 1.
2.Invert the cap so that the letters appear that represent the gas type appropriate for the appliance. NAT for natural manufactured gas, LP for liquid petroleum gas.
3.Replace the cap and tighten firmly.
Fig. 1. Top view of convertible pressure regulator
cap.
Install Adapters To Control
If adapters are being installed on the control, mount them as follows:
Flanges
1.Choose the appropriate flange for your application.
2.Remove the seal over the ignition system control inlet or outlet.
3.Make sure that the
4.With the
1
VALVE OUTLET
FLANGE
9/64 INCH HEX SCREWS (4)
1 DO NOT OVERTIGHTEN SCREWS. TIGHTEN TO |
|
25 | M9046 |
Fig. 2. Firmly fasten flange to valve, but do not
overtighten screws.
Bushings
1.Remove the seal over the control inlet or outlet.
2.Apply a moderate amount of good quality pipe compound to the bushing, leaving two end threads bare. On an LP installation, use compound that is resistant to LP gas. Do not use Teflon tape.
3.Insert the bushing in the control and carefully thread the pipe into the bushing until tight.