VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS
CAUTION
Equipment Damage.
Can burn out valve coil terminals.
Never apply a jumper across (or short) the valve coil terminals, even temporarily.
After servicing, verify proper system operation.
If Main Burner Does Not Come On With Call For Heat
1.Confirm the gas control knob is in the ON position.
2.Adjust thermostat several degrees above room temperature.
3.Using ac voltmeter, measure across MV terminals at gas control.
4.If voltage is incorrect or not present, check control circuit for proper operation.
5.If proper voltage is present, replace gas control.
INSTRUCTIONS TO THE
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury, or death.
Follow these warnings exactly:
1.Before lighting, smell around the appliance for gas. Be sure to smell next to the floor because LP gas is heavier than air. If you smell gas:
(a)•Turn off the gas supply at the appliance service valve. On LP gas systems, turn off the gas supply at the gas tank.
(b)•Do not light any appliances in the house.
(c)•Do not touch electrical switches or use the phone.
(d)•Leave the building and use a neigh- bor’s phone to call your gas supplier.
(e)•If you cannot reach your gas supplier, call the fire department.
2.Replace the gas control in the event of any physical damage, tampering, bent terminals, missing or broken parts, stripped threads, or evidence of exposure to heat.
IMPORTANT
Follow the operating instructions provided by the heating appliance manufacturer. The information below describes a typical control application, but the specific controls used and the procedures outlined in your appliance manufacturer instructions can differ, requiring special instructions.
To Turn ON Appliance
STOP: Read the Warnings Above Before Proceeding
1.The lighting sequence on this appliance is automatic; do not attempt to manually light the main burner.
2.If the furnace does not come on when the thermostat is set several degrees above room temperature, set the thermostat to its lowest setting to reset the safety control.
3.Remove the burner access panel if provided on your appliance.
Turn the gas control knob clockwise to OFF.
4.Wait five minutes to allow any gas in the combustion chamber to vent. Then if you smell gas, STOP! Follow Step 1 in the Warning above. If
you do not smell gas, continue with the next step. If you do not smell gas, turn knob on gas control
counterclockwise to ON.
5.Replace the burner access panel.
6.Reset the thermostat to the desired temperature.
7.If the appliance does not turn on, turn the gas control knob to OFF and contact a qualified service technician for assistance.
Turning Off the Appliance
Vacation Shutdown
Set the thermostat to the desired room temperature while you are away.
Complete Shutdown
Turn off power to the appliance. Turn off the gas supply to the appliance. Turn gas control knob clockwise
to OFF. Appliance will completely shut off. Follow the procedure in the Instructions to the Homeowner section above to resume normal operation.
11 |