VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS
WHEN FLANGE IS NOT USED | WHEN FLANGE IS USED |
APPLY WRENCH | APPLY WRENCH |
FROM TOP OR | TO FLANGE ONLY |
BOTTOM OF GAS |
|
CONTROL TO |
|
EITHER SHADED AREA |
|
M3084A
Fig. 5. Proper use of wrench on gas control with and without flanges.
ADJUSTMENT SCREWS (UNDER CAP)
REGULATOR
VENT COVER
LO |
HI |
PRESSURE REGULATOR | WIRING | |
ADJUSTMENT (UNDER | TERMINALS (2) | |
CAP SCREW) | OUTLET | |
PRESSURE | ||
| ||
INLET | TAP | |
PRESSURE TAP |
|
OUTLET
PRESSURE
REGULATOR
INLET MODEL
INLET
GAS CONTROL KNOB
M10967A
Fig. 6. Top view of gas control.
Wiring
Follow the wiring instructions furnished by the appliance manufacturer, if available, or use the general instructions provided below. When these instructions differ from the appliance manufacturer, follow the appliance manufacturer instructions.
All wiring must comply with applicable electrical codes and ordinances.
Disconnect power supply before making wiring connections to prevent electrical shock or equipment damage.
1.Check the power supply rating on the gas control and make sure it matches the available supply. Install a transformer and other controls as required.
2.Connect the control circuit to the gas control terminals. See Fig. 7 and 8.
3.Adjust thermostat heat anticipator to 0.50A rating stamped on valve operator.
6 |