IX. DIAGNOSTIC LEDs

The motor control is designed with LEDs mounted on the front cover to display the control’s operational status.

A.Power On (ON) – Indicates the presence of bus voltage.

B.Status (STATUS) – The Status LED is a tricolor LED that provides indication of the con- trol’s operational status including installation problems such as incorrect input voltage, overvoltage, undervoltage and control miswiring. It also provides a "normal" indication if all control and microcontroller operating parameters are proper. See Table 5 on page 12.

X.OPTIONAL ACCESSORIES

Complete instructions and connection diagrams are supplied with all accessories to facilitate installation.

A.Forward-Stop-Reverse Switch (ID5FSR-1) – Provides motor reversing and stop func- tions. Mounts on the enclosure cover and is supplied with a switch seal to maintain water- tight integrity.

B.Signal Isolator/Run Relay (ID5SI-2) – Provides isolation between a non-isolated signal voltage source and the drive and contains a Run Relay which can be used to turn on or off equipment or to signal a warning if the control is put into the Stop Mode or a fault has occured.

C.Auto/Manual Switch (ID5AMS-1) – When used with the ID5SI-2, it either selects an iso- lated signal from the ID5SI-2 or the Main Speed Potentiometer. Mounts on the enclosure cover and is supplied with a switch seal to maintain watertight integrity.

13

Page 15
Image 15
Baldor IP-65, NEMA 4X manual Optional Accessories