Baldor IP-65, NEMA 4X manual Optional Accessories

Models: NEMA 4X IP-65

1 16
Download 16 pages 59.38 Kb
Page 15
Image 15

IX. DIAGNOSTIC LEDs

The motor control is designed with LEDs mounted on the front cover to display the control’s operational status.

A.Power On (ON) – Indicates the presence of bus voltage.

B.Status (STATUS) – The Status LED is a tricolor LED that provides indication of the con- trol’s operational status including installation problems such as incorrect input voltage, overvoltage, undervoltage and control miswiring. It also provides a "normal" indication if all control and microcontroller operating parameters are proper. See Table 5 on page 12.

X.OPTIONAL ACCESSORIES

Complete instructions and connection diagrams are supplied with all accessories to facilitate installation.

A.Forward-Stop-Reverse Switch (ID5FSR-1) – Provides motor reversing and stop func- tions. Mounts on the enclosure cover and is supplied with a switch seal to maintain water- tight integrity.

B.Signal Isolator/Run Relay (ID5SI-2) – Provides isolation between a non-isolated signal voltage source and the drive and contains a Run Relay which can be used to turn on or off equipment or to signal a warning if the control is put into the Stop Mode or a fault has occured.

C.Auto/Manual Switch (ID5AMS-1) – When used with the ID5SI-2, it either selects an iso- lated signal from the ID5SI-2 or the Main Speed Potentiometer. Mounts on the enclosure cover and is supplied with a switch seal to maintain watertight integrity.

13

Page 15
Image 15
Baldor IP-65, NEMA 4X manual Optional Accessories