13. Input Source File Ser vice
OSD
EDIT FILE video625.C05
HORIZONTAL
TOTAL 864 PIXELS
ACTIVE 692 PIXELS
START 130 PIXELS
PERIOD 64.000 us
VERTICAL (FIELD)
TOTAL 313 LINES
ACTIVE 278 LINES
START 29 LINES
INTERLACED [ON]
READ AMDS
OPTIONS
−, /, ,, .,
<ENTER>, <EXIT>
064.000
064.000
12
4
3
064.000
5
RCU
ENTER
EXIT

Image13-7

adjustingthe value itself with the digit buttons on the Remote Control

1Presstheor cursor key to select item to be changed
2 Press ENTER to activate the bar scale
3 Press ENTER to activate value number in bar scale

4 Pressthe digit button on the RCU to put a new value number

5Presstheor cursor key to jump to the next number
6 Press ENTER to save value change
7 Press EXIT to return
Setting between brackets

1. Select item to be changed, using or cursor key, and follows instructions as indicated in drawing. (image 13-8)

OSD
ADJ EXIT
ENTER
PAUSE
PHASE
TEXT
SHARPN
90
EDIT FILE video625.C05
HORIZONTAL
TOTAL 864 PIXELS
ACTIVE 692 PIXELS
START 130 PIXELS
PERIOD 64.000 us
VERTICAL (FIELD)
TOTAL 313 LINES
ACTIVE 278 LINES
START 29 LINES
INTERLACED [ ON ]
READ AMDS
OPTIONS
−, /, ,, .,
<ENTER>, <EXIT>
RCU
12 3
ON OFF
EXIT
ENTER

Image13-8

Functionsetting using ENTER button as toggle key

1Presstheorcursor key to select item to be changed

2 PressE NTER to change the setting

7 Press EXIT to return
13.5.2 Changing the parameter settings with the selection wheelHow to use the selection wheel

1. Rotate the selection wheel to scroll through the menus or to change values.

2. Press the selection wheel to toggle or confirm.

3. Select RETURN in the menus , followed by pressingthe s electionwheel to return.

R5976519 ACSAR 12122002 59