14.3.16Shutdown

14.3.17Operating System Shutdown

When the client computer is been shut down, the Barracuda NG Access Monitor will send a logoff command to switch, causing the line protocol being disabled by the switch.

14.3.18Operating System Logoff

When a user logs off his account from the operating system, the Barracuda NG Access Monitor follows the same procedure as above.

14.3.19Manual Logoff

It is possible, if required, to logoff manually using the Barracuda NG Access Monitor. To do so take following steps:

Enter the Barracuda NG Access Monitor Port Security section

Select the network interface to log off

Choose "Logoff" from the tasks menu on the left or through the context menu of the network interface

To verify the logoff command was sent and executed properly, verbose output is required and needs to show the following:

Table 14–14 phions.log

Output

[009003002002] sent command LOGOFF with answer [009003002003] about success

Table 14–15 phions.log

Output

 

[009002009001]

monitor destroying

For every supplicant

[009003002002] sent

command

LOGOFF with answer [009003002003] about success

 

[009003002002]

sent

command

TERMINATE with answer [009003002003] about success

 

[009003009003]

thread for adapter … ended

 

[009002009009]

monitor destroyed

 

 

 

 

 

198 802.1X – Technical Guideline

Page 200
Image 200
Barracuda Networks VERSION SP4 manual Shutdown, phions.log Output