199 Barracuda NG Network Access Client - Administrator’s Guide

14.4 Addendum

14.4.1 Packets

The table shows an EAPOL packet frame:

The table below shows the fields of the EAP request-response frame:

14.4.2 WPA Supplicant Log File Identifiers

Table 14–16 EAPOL packet frame
Field Name Size Purpose
Version 1 Byte Protocol version
Type 1 Byte 1 Start
2 Logoff
Length 2 Bytes Length of the EAP packet
Data (EAP) N Bytes EAP packet
Table 14–17 Fields of the EAP request-response frame
Field Name Size Purpose
Code
1 Byte 1 Request
2 Response
3 Success
4 Failure
Identifier 1 Byte To match request-response
Length 2 Byte Length of total packet includes
Type 1 Byte 1 Identify
25 PEAP request Protected EAP communication
Data N Byte
Table 14–18 WPA Supplicant Log File Identifiers
009 000 000 000 wpa_supplicant control
009 001 000 001 802.1x monitoring state (enabled/disabled)
002 reloading adapter list
004 stating adapter type and if it's added to list
006 802.1x disabled for this adapter
005 invalid values in adapter list
008 excluding non-ethernet adapter