The following entities are available for rule testing:

List 3–4Rule Tester parameters – section TEST CONNECTION

Parameter

Description

 

 

Direction

This is the direction of the traffic policy (Incoming or Outgoing).

 

 

Application

To query for an arbitrary application leave the asterisk (*), which is set as default value. Click the Application link and Select

 

Update Applications to reset the field to the default value.

 

 

From: IP / Port

Insert Source IP and corresponding connection port. Click the From or To link to Swap IP and/or Port information.

 

 

Protocol

Specify which protocol to test. Click the Protocol link and select Show all Protocols to include other protocols than TCP/UDP and

 

ICMP into the list.

 

 

Time (optional)

Insert day of the week and time (optionally). Click the Time link and select Insert current Time to insert current day and time.

 

 

User (optional)

Select an User from the list (Optionally). Click the User link and select Update Users to clear the field.

 

 

Adapter

Select an adapter from the list (Optionally). Click the Adapter link and select Update Adapters to clear the field.

(optional)

 

 

 

Test

Click Test to test the connection and display the test result in the section below.

 

 

List 3–5Rule Tester parameters – section TEST RESULT

Parameter

Description

 

 

Test Status Icon /

A connection attempt with the given values can either have failed or have been successful if a rule is applicable. A failed

Action

connection will be indicated by symbol and Action field Block . A successful connection attempt will be indicated by

 

symbol and Action field Pass .

 

 

Rule

The Rule field displays the applicable rule responsible for the rule test result. Click Edit… to open and modify the

 

corresponding rule. If the connection attempt has been blocked because no rule has applied, the field will display the string

 

<No Matching Rule Found>.

 

 

Service

This field displays the applicable Service Object.

 

 

PlugIn

If applicable, this field displays the name of the PlugIn that has been employed in the connection.

 

 

Save Result to

Insert the report name and click Save Result to to save the test result. The output of the connection test is written to the

 

Test Report view (3.2.6 Test Report, page 48).

 

 

Attribute/Value listing

This listing displays attributes of the tested connection in detail.

 

 

3.2.6Test Report

Fig. 3–7Test Report window

Test reports are saved on a first come first served basis. Test results with Action Pass are indicated by a green icon (), test results with Action Blocked are indicated by a red icon ().

48 Server Config – Personal Firewall Rules

Page 50
Image 50
Barracuda Networks VERSION SP4 manual Test Report, Following entities are available for rule testing