By responding to the Enter Request: message at the end of the main configuration menu (see Section 6.1) with "5" (Set Control Character), you may change the control character.

WARNING: BayTech advises you to log your new control character. If it is forgotten, you will not be able to control the unit or access the configuration mode.

CONTROL

CHARACTER____________ DATE______ BY___

CONTROL

CHARACTER____________ DATE______ BY___

The multiport will respond with:

Current Control Character is

14H

Enter Control Character in Hex

:

You may now enter the new control character that you want in HEX (00 to 7F Hex). For example, if you enter "15 " (Control-U), the multiport will respond with:

Current Control Character

is

15H

Save Changes Permanently?

(Y/N):

 

If you answer "Y" (yes), the new control character will be saved in non-volatile memory, and the multiport will respond only to that character. The multiport will respond with:

Are You Sure? (Y/N):

This message gives you a second chance to consider this change and reminds you to log your new control character. If you answer either question with "N" (no), the new control character will be stored in RAM and lost upon next power-up. The multiport will return to the main configuration menu (see Section 6.1).

Page 36
Image 36
Bay Technical Associates 5218H, 528H, 529H, 525H owner manual Control