For example, to configure Port 2 in the
^TI^TC22*233343526Y130A4250*51466X.
This breaks down as follows:
^T indicates control character.
Iindicates
2 indicates Set Serial Port Configuration.
2 indicates Port 2.
* indicates Carriage Return.
2 indicates Set Baud Rate.
3 indicates 300 Baud.
3 indicates Set Word Size.
3 indicates 7 Word Size.
4 indicates Set Stop Bits.
3 indicates 2 Stop Bits.
5 indicates Set Parity.
2 indicates Even Parity.
6 indicates Set XON/XOFF.
Y indicates XON/XOFF enabled.
1 indicates Exit to Main Menu.
3 indicates Set Message Terminate Character.
0A indicates Line Feed Terminating Character in Hex.
4 indicates Set Data Block Length.
250 indicates Data Block Length. * indicates Carriage Return.
5 indicates Set Control Character.
14 indicates
6 indicates Set Mode of Operation.
6 indicates Mode of Operation 6.
X indicates Exit to Operation Mode.