For example, to configure Port 2 in the non-verbose mode at 300 baud rate, 7 bit word size, 2 stop bits, even parity, XON/XOFF enabled, line feed terminating character, data block length 250, control character Control-T, mode of operation 6, and XON/XOFF enabled, send the following character string:

^TI^TC22*233343526Y130A4250*51466X.

This breaks down as follows:

^T indicates control character.

Iindicates non-verbose mode. ^T indicates control character. C indicates Configuration Mode.

2 indicates Set Serial Port Configuration.

2 indicates Port 2.

* indicates Carriage Return.

2 indicates Set Baud Rate.

3 indicates 300 Baud.

3 indicates Set Word Size.

3 indicates 7 Word Size.

4 indicates Set Stop Bits.

3 indicates 2 Stop Bits.

5 indicates Set Parity.

2 indicates Even Parity.

6 indicates Set XON/XOFF.

Y indicates XON/XOFF enabled.

1 indicates Exit to Main Menu.

3 indicates Set Message Terminate Character.

0A indicates Line Feed Terminating Character in Hex.

4 indicates Set Data Block Length.

250 indicates Data Block Length. * indicates Carriage Return.

5 indicates Set Control Character.

14 indicates Control-Tin HEX.

6 indicates Set Mode of Operation.

6 indicates Mode of Operation 6.

X indicates Exit to Operation Mode.

Page 40
Image 40
Bay Technical Associates 5218H, 528H, 529H, 525H owner manual TITC22*233343526Y130A4250*51466X