Additional Information
Replacing the Lamp (Contact your BenQ dealer for assistance)
CAUTION: The lamp may be very hot. Allow the projector to cool down for 45 minutes before replacing the lamp.
1.Turn the power off and disconnect the projector from
the wall socket.
2. Use a Phillips screwdriver to loosen the screw (a) securing the lamp cover and then remove the cover from the projector.
3. Use a Phillips screwdriver to loosen the three screws (b) securing the lamp box.
4. Lift the handle so that it stands up.
5.Use the handle to slowly pull the lamp out of the
projector.
Pulling it too quickly may cause broken glass to scatter about if the bulb has broken.
Do not place the lamp in locations where water might splash on it, children can reach it, or near flammable materials.
Do not insert your hands into the box after the lamp is |
|
removed. If you touch the optical component inside, it could |
|
cause color unevenness and distortion of the projected |
|
images. | Handle |
6. Insert a new lamp. Make sure the handle is fully locked.
7. Use a Phillips screwdriver to tighten the three screws
(b) securing the lamp box.
Loose screws may cause a bad connection, which could result in malfunction.
Do not over tighten the screws.
8.
9. Turn the power on.
■ Power will not turn on while the lamp cover is off.
Resetting the lamp counter |
|
10. On the control panel, simultaneously press and hold | Handle |
|
the S, T, and POWER buttons for at least 3 seconds.
■Once the lamp life exceeds 1,500 hours, the lamp will not light, even after you replace it. The lamp counter must be reset as soon as a new lamp is installed.
■ Do not reset the lamp life without replacing the lamp.
S button
T button
Power button
Additional Information | 29 |