Troubleshooting
WARNING:
To reduce the risk of fire, electric shock or injury unplug from outlet before servicing.
SmartTemp Ready Light does not illuminate.
Possible Causes | Remedies |
|
The SmartTemp switch is not | Turn on the SmartTemp switch. | |
turned ON. |
|
|
The machine Power Switch is not | Both switches must be ON to | |
turned ON. | activate the SmartTemp Ready Light. |
Reduced spray or no spray |
|
Possible Causes | Remedies |
Bladder may be empty. | Refill bladder with hot tap water. |
SmartMix bottle may be empty. | Fill with BISSELL Advanced Cleaning |
| Formula for cleaning or water if |
| rinsing,or using the Scotchgard |
| protector applicator. |
The filter may be clogged.
Tanks may not be seated properly.
Pump may have lost prime.
The Pump Belt may be broken.
Lift Here
Insert
Screwdriver
Blade Here
Clean out Flow Indicator Filter, page 17.
Turn power OFF; remove & reseat tanks. Inspect for presence of seals.
Turn power OFF; after 1 minute turn ON and depress trigger.
Turn the machine OFF and unplug from the outlet. To check if a Pump Belt has broken, you will need a flat head screwdriver. Insert the blade end into the lower slot of the Belt Access door to release the lower snap. If necessary, insert the blade end into the upper slot to release the upper snap. Examine the belt for breakage. You should be able to see the Pump Belt looped around the motor shaft. If it is broken or missing, please refer to Replacement Parts on pg.23 before calling Consumer Services. Complete installation instructions will accompany the replacement belt.