RS422/485 SERIAL INTERFACE PLUS

RS-530 and RS-449

RS-530 and RS-449 (EIA-530 and EIA-449) are similar to RS-422 and RS-485 in the fact that they are differential interfaces, but these two standards provide a specified pin-out that defines a full set of modem control signals that can be used for regulating flow control and line status. RS-449 is defined on a standard 37-pin D sub-connector, while RS-530 is backward-compatible and is replacing RS-449. RS-530 is defined on a 25-pin D sub-connector.

TX+

RX+

TX-

RX-

RX+

TX+

RX-

TX-

Figure 2-1. RS-422/530 Connection.

RS-485

This interface is very similar to RS-422 is several ways. RS-485 is a differential interface that allows cable lengths up to 5000 feet (1524 m) and data rates up to 10 Mbps. The signal levels for RS-485 are the same as those defined by RS-

422.RS-485 has electrical characteristics that allow for

32drivers and 32 receivers to be connected to one line.

4

Page 9
Image 9
Black Box IC171C manual RS-422/530 Connection