CHAPTER 3: Installation

NOTE

Both ends of the T- connector must be attached to network cabling. If the Adapter is at the end of a network segment, the end of the T-connector not attached to the network must have a 50-ohm terminator installed.

3.2.3 LE075A

For the Modular Parallel Adapter for AUI, refer to Fig. 3-4.

After connecting the connector, press the slide latch to the left to lock the connector into place.

NOTE

For use with an external power supply only. Not to be used with the SPC!

Fig. 3-4. Connecting an AUI Cable to the Media Unit.

9

Page 10
Image 10
Black Box LE171, LE172, LE075A-R2, LE073AE-R2, LE074AE-R2, LE072A, LE076A Connecting an AUI Cable to the Media Unit, 3 LE075A