MULTI-FUNCTION LD CARD

S1 Positions 1 through 4: Data-Rate Setting

Set positions 1 through 4 of switch S1 to determine the data rate (valid for both synchronous and asynchronous protocols) of the Multi-Function LD Card.

S1-1

S1-2

S1-3

S1-4

Data Rate

On

On

On

On

1.2 kbps

Off

On

On

On

1.8 kbps

On

Off

On

On

2.4 kbps

Off

Off

On

On

3.6 kbps

On

On

Off

On

4.8 kbps

Off

On

Off

On

7.2 kbps

On

Off

Off

On

9.6 kbps (default)

Off

Off

Off

On

14.4 kbps

On

On

On

Off

19.2 kbps

Off

On

On

Off

28.8 kbps

On

On

Off

Off

38.4 kbps

Off

On

Off

Off

57.6 kbps

S1 Positions 5 and 6: Clock Source

Set positions 5 and 6 of switch S1 to determine which transmit-clock source the Multi-Function LD Card uses.

S1-5

S1-6

Clock Source

On

On

Internal transmit clock (default)

Off

On

Receive-recover clock

On

Off

External transmit clock

S1 Position 7: Protocol

Set position 7 of switch S1 to determine whether the Multi-Function LD Card operates synchronously or asynchronously.

S1-7

Protocol

On

Asynchronous (default)

Off

Synchronous

12